background image

C

R

D

2

7

0

0

-

4

0

0

0

E

E

t

h

e

r

n

e

t

C

r

a

d

l

e

Summary of Contents for CRD 2700-4000E

Page 1: ...C R D 2 7 0 0 4 0 0 0 E E t h e r n e t C r a d l e ...

Page 2: ...9 591 5 230 088 5 235 167 5 243 655 5 247 162 5 250 791 5 250 792 5 260 553 5 262 627 5 262 628 5 266 787 5 278 398 5 280 162 5 280 163 5 280 164 5 280 498 5 304 786 5 304 788 5 306 900 5 321 246 5 324 924 5 337 361 5 367 151 5 373 148 5 378 882 5 396 053 5 396 055 5 399 846 5 408 081 5 410 139 5 410 140 5 412 198 5 418 812 5 420 411 5 436 440 5 444 231 5 449 891 5 449 893 5 468 949 5 471 042 5 47...

Page 3: ...ommunicate simultaneously with a single host then synchronization server software such as Scout MTSTM or AVANTGOTM is required This software may be purchased from Symbol Contact your Symbol sales representative for information About This Guide This guide provides instruction on setting up and using the CRD2700 4000E 4 slot Ethernet cradle as well as setting up an SPT 1700 or PPT 2700 terminal for ...

Page 4: ...ence Guide for instructions on installing the software Unpacking the Cradle The shipping box includes the following One 4 slot cradle p n CRD2700 4000E This Quick Reference Guide p n 72 50357 xx No Ethernet cable is shipped with the cradle but is required to connect the cradle to an Ethernet hub You will also need 8Volt 5Ampere power supply p n 50 14000 109 AC line cord If any parts are missing or...

Page 5: ... network cable to the connector labelled Host on the back of the CRD2700 4000E Connect the other end of the cable to a hub which is connected to your subnet 3 Connect the Power Supply AC plug to a standard electrical outlet Note International customers must use a separate AC line cord appropriate for their respective country 4 The LED on each slot blinks red then green while the cradle attempts to...

Page 6: ...elay agent on the same subnet as the CRD2700 4000E for the unit to be automatically configured with IP addresses a gateway IP address 2 DNS addresses at least one WINS server address and a subnet mask The cradle acquires 6 IP addresses from the DHCP server These addresses are allocated as follows one for the cradle one for the expansion port and one for each slot 4 Caution For the cradle to work p...

Page 7: ...erver one for the cradle one for each of the 4 slots and one for the expansion slot This feature is not enabled when using NAPT translation To perform this configuration run the EFlasher utility from the debug monitor Follow steps 1 through 6 in Static Mode to access the Current Cradle Globals menu 1 Select option 1 for Static mode Set both Static Mode and NAPT Mode to 0 to acquire 6 IP addresses ...

Page 8: ...hould be connected to a COM port on the PC and should be set to run at 115200 bps 8N1 with XON XOFF flow control and ASCII file transfer protocol using a terminal emulator soft ware such as ProCommTM or HyperterminalTM 2 Connect the modular end to the expansion port of the CRD2700 4000E 3 Power up the CRD2700 4000E Before the power up LED sequence begins type a from the terminal program to enter t...

Page 9: ...sion x xx I Flash Info P Program Cradle Globals Q Quit 1 Public network settings 2 Advanced settings 3 PPP network settings 4 Private network settings Public Network 1 Static mode 1 2 NAPT Mode 0 The following settings are only used when Static mode 3 Cradle IP Address 10 0 3 1 4 Router Gateway IP Address 10 0 0 1 5 1st DNS IP Address 10 0 1 1 6 2nd DNS IP Address 0 0 0 0 7 1st WINS IP Address 10 ...

Page 10: ...ss must be re served for this CRD2700 4000E See your network adminis trator for assistance 10 Select option 4 and update the Router IP address This ad dress should be set to the IP address of your internet gate way 11 Select option 5 and 6 and set the DNS IP addresses for DNS1 and DNS 2 12 Select option 7 and 8 to set the WINS addresses This is re quired for Active Sync to function properly 13 Sel...

Page 11: ...e addresses specified in options A E in the Public network menu above The cradle modifies one IP address and port number pair inside a TCP IP and UDP IP packet header Those packets going to the outside network have their source address translated to the IP address of the cradle and their source port changed to a unique port number associated with the cradle slot it came from Conversely packets des...

Page 12: ...vices may reply with data over a range of ports These network services are unusable with the CRD2700 4000E Also some services listen to incoming requests from the network Since port numbers are usually fixed for a given service no Palm terminals can be set up as listeners Inter Connecting Cradles Up to four 4 slot CRD1700 4000S serial cradles may be inter connected daisy chained with the CRD2700 4...

Page 13: ...nd PPT 2700 terminals inserted into the cradle as a direct connect PPP service Therefore just as you would set up any remote client to connect to an Internet Service Provider ISP like Compuserve or Earthlink the terminals must be configured for use with the cradle The following sections describe the steps necessary to configure the SPT 1700 and PPT 2700 terminals Configuring the SPT 1700 Configuri...

Page 14: ...st Setup d Using the PC you will synchronize with most often right click on the HotSync Manager in the Windows tray on the host PC Left click on Setup click on the Network tab then click on the TCP IP Settings button Note the Pri mary PC Name Primary PC address and the Subnet mask and enter that information manually on your SPT 1700 Note If the Subnet Mask box on your PC is empty you do not need t...

Page 15: ...00E via a Modem Sync The Modem Sync offers many options which must be configured for use with the CRD2700 4000E Create a separate CRD2700 4000E network configuration and select it as your default Modem Sync service Use either Graffiti or the keyboard feature click in the lower left hand corner of the scratch pad on the abc to access the keyboard to enter the following information 1 Select the HotS...

Page 16: ...e operate simultaneously If multiple slots are to be HotSync d simultaneously each must communicate with a different host PC If the application requires simultaneous connection to a single host database additional software available from Symbol is required Terminals inserted into daisy chained cradles are HotSync d in a round robin fashion simultaneously with any HotSyncs from local slots Daisy ch...

Page 17: ...l panel applet that is installed in the terminal and allows any custom synchronization application to be launched when the terminal is inserted into the cradle eConnect can be set up to start a TCP IP connection with the cradle allowing any IP based application to communicate through the cradle Configuring the Remote Host PC For the PPT 2700 terminal to Active Sync with the host computer a partner...

Page 18: ...r Active Sync to function Insert the PPT 2700 terminal into the cradle and initiate ActiveSync 1 From the Start menu select Programs 2 Tap the Connections icon to select the connection options 3 Tap the ActiveSync icon 4 In the ActiveSync dialog select 115200 Default from the drop down list 5 Select the proper host computer in the Connect To box Note that in order for a host to appear in this list...

Page 19: ...onnect Using Selection to 115200 Default Battery Charging The CRD2700 4000E can also be used to recharge the battery in the terminal All four slots can be used to simultaneously recharge the batteries on four terminals To charge the battery insert the terminal s in the slot s The battery begins to charge It takes approximately 2 hours to recharge the battery After two hours remove the terminal fro...

Page 20: ... All LEDs Red Flashing Automatic configuration of the cradle via the local DHCP service failed Connect a properly configured DHCP server or DHCP relay agent to the subnet and power cy cle the CRD2700 4000E or wait 10 minutes for a DHCP configuration retry Or Ethernet link is down Make sure the ethernet cable is connected to an active hub Symptom Cause Suggested Action LEDs do not light when the cr...

Page 21: ... the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Re orient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that which the receiver is connected Consult the dealer or an experienced radio TV technician for help Atte...

Page 22: ... 1995 01 Electromagnetic compatibility EMC Part 4 Testing and measurement techniques Section 2 Electrostatic discharge immunity test IEC 1000 4 3 1995 03 Electromagnetic compatibility EMC Part 4 Testing and measurement techniques Section 3 Radiated radio frequency electro magnetic field immunity test IEC 1000 4 4 1995 01 Electromagnetic compatibility EMC Part 4 Testing and measurement techniques S...

Page 23: ... Symbol will issue a Return Material Authorization Number Products must be shipped in the original or comparable packaging shipping and insurance charges prepaid Symbol will ship the repaired or replacement product freight and insurance prepaid in North America Shipments from the US or other locations will be made F O B Symbol s manufacturing plant Symbol will use new or refurbished parts at its d...

Page 24: ...the equipment they will contact the Symbol Support Center United States 1 800 653 5350 Canada 905 629 7226 United Kingdom 0800 328 2424 Asia Pacific 337 6588 Australia 1 800 672 906 Austria 1 505 5794 Denmark 7020 1718 Finland 9 5407 580 France 01 40 96 52 21 Germany 6074 49020 Italy 2 484441 Mexico 5 520 1835 Netherlands 315 271700 Norway 66810600 South Africa 11 4405668 Spain 9 1 320 39 09 Swede...

Reviews: