Sygonix 1456298 Operating Instructions Manual Download Page 6

This is a publication by Conrad Electronic SE, Klaus‑Conrad‑Str. 1, D‑92240 Hirschau (www.conrad.com). 
All rights including translation reserved. Reproduction by any method, e.g. photocopy, microfilming, or the capture in 

electronic data processing systems require the prior written approval by the editor. Reprinting, also in part, is prohibited. 

This publication represents the technical status at the time of printing.
Copyright 2016 by Conrad Electronic SE. 

  

*1456298_V2_0816_02_IPL_m_en

Tips and notes

•  The following setting is suitable for drying clothes:

 - Humidity: 40 %
 - Fan speed: H

 (high)

•  When using the product at room temperatures b5 and +12 °C, the dehumidifying 

operation will be paused every 30 minutes in order for the product to perform the automatic 

defrost function.

•  When using the product at room temperatures b12 and +20 °C, the dehumidifying 

operation will be paused every 45 minutes in order for the product to perform the automatic 

defrost function.

•  When the current ambient humidity undercuts the set value by 2 %, the compressor stops 

operation. The fan will stop after another 3 minutes.

•  Once the current ambient humidity is equal to or higher than the set value, the compressor 

will start again after 3 minutes.

Cleaning and care

a) General

•  Disconnect the product from the mains supply before cleaning. 
•  Under no circumstances use aggressive cleanings agents, cleaning alcohol or other chemical 

solutions since these can penetrate the housing or impair functionality.

• 

Clean the product with a dry, fibre‑free cloth.

b) 

Water tank

•  If the water tank is dirty, rinse it with lukewarm water.
•  Do not use any coarse sponge.

c) 

Air filter

• 

Never use the product without the air filter.

• 

Clean the air filter with utmost care in order not to damage it.

• 

The air filter should be cleaned every 4 weeks, depending on the operating conditions.

• 

Remove the air filter frame.

• 

Clean the air filter with a soft brush, with compressed air, or with a vacuum cleaner at low 

setting.

• 

In case of heavy staining, rinse the air filter carefully using lukewarm water and some mild 

detergent. Let the air filter dry completely before reinstalling.

Storage

•  Empty the water tank.
• 

Clean the air filter.

•  You can store the cable inside the empty, dry water tank. Guide the cable through the left 

recess above the water tank.

•  Store the product at a cool, dry location.

Troubleshooting

Problem

Cause

Solution

The product does not work.

The mains plug is not 

properly connected to the 

wall socket.

Make sure the mains plug 

is properly connected to the 

wall socket.

The water tank is full or not 

properly installed.

Empty the water tank or 

make sure the tank is 

properly installed.

The ambient temperature 

is above +35 °C or below 

+5 °C.

Observe the operating 

conditions.

The dehumidifying function 

or the air outlet does not 

work.

The air filter is clogged or 

dirty.

Clean the air filter.

The air inlet/outlet is 

blocked.

Remove the blocking object.

The product is too loud.

The product is not in upright 

position.

Place the product on a 

flat, horizontal and stable 

surface.

The air filter is clogged or 

dirty.

Clean the air filter.

Disposal

  Electronic devices are recyclable waste and must not be disposed of in the 

household waste. At the end of its service life, dispose of the product in accordance 

with applicable regulatory guidelines.

 

You  thus  fulfil  your  statutory  obligations  and  contribute  to  the  protection  of  the 

environment.

Technical data

Operating voltage ......................... 220 – 240 V/AC, 50 Hz
Dehumidifying power .................... 22 L per day
Water tank capacity ...................... 4.2 L
Power consumption ...................... 410 W
Noise level ....................................

≤43 dB(A)

Airflow

 ........................................... 200 m

3

/h

Coolant .........................................

R134a (160 g)

Room size ..................................... 44 m

2

Vent slot angle .............................. 30 – 90º
Tube connection Ø .......................

10/13 mm (internal/external)

Protection type .............................. IP21
Cable length ................................. 1.5 m
Operating conditions ..................... +5 to +35 ºC, 35 – 95 % RH
Storage conditions ........................ +5 to +45 ºC, 30 – 95 % RH

Dimensions (W x H x D)

 ............... 322 x 548 x 246 mm

Weight .......................................... 12.25 kg

Summary of Contents for 1456298

Page 1: ...rsetzt werden um Gef hrdungen zu vermeiden Netzstecker d rfen nie mit nassen H nden ein oder ausgesteckt werden Transportieren Sie das Ger t nur am Tragegriff Stellen Sie keine Gegenst nde auf das Pro...

Page 2: ...ukt nach Ablauf von 10 Stunden automatisch ein Um die automatische Einschaltfunktion zu deaktivieren schalten Sie das Produkt entweder manuell ein oder stellen Sie den Timer auf den Wert 00 Ausschaltz...

Page 3: ...us Verwenden Sie keinen rauen Schwamm c Luftfilter Betreiben Sie das Produkt nie ohne den Luftfilter Reinigen Sie den Luftfilter mit gr ter Vorsicht um ihn nicht zu besch digen Der Luftfilter sollte j...

Page 4: ...ock any ventilation slots on the device in order to ensure proper cooling Do not insert objects or fingers into the device Never leave the product unattended during use Do not point the air outlet at...

Page 5: ...the set value If you select a value of 10 hours the product will turn off automatically after 10 hours In order to deactivate the automatic switch off function switch the product off manually or reset...

Page 6: ...ating conditions Remove the air filter frame Clean the air filter with a soft brush with compressed air or with a vacuum cleaner at low setting In case of heavy staining rinse the air filter carefully...

Page 7: ...n d alimentation endommag doit seulement tre remplac par le fabricant un atelier habilit par celui ci ou une personne qualifi e Ne jamais brancher ou d brancher la fiche de secteur avec les mains moui...

Page 8: ...s allume en permanence La valeur r gl e appara t sur l cran d affichage Si vous r glez par exemple la valeur 10 le produit se met en marche automatiquement pass le d lai de 10 heures Pour d sactiver...

Page 9: ...amais fonctionner le produit sans son filtre air Nettoyez le filtre air avec pr caution pour ne pas l endommager Selon les conditions de fonctionnement le filtre air devrait tre nettoy toutes les 4 se...

Page 10: ...et stopcontact steken of eruit trekken Verplaats het apparaat alleen door het vast te houden aan de daarvoor bestemde greep Plaats nooit voorwerpen op het product en dek het nooit af Blokkeer de venti...

Page 11: ...product aangezet zijn Druk op toets TIMER om de gewenste tijd in stappen van 1 uur voor een periode van 1 tot 24 uur in te stellen De bij de toets behorende LED brandt dan continu Op het beeldscherm...

Page 12: ...n de gebruiksomstandigheden om de 4 weken schoon worden gemaakt Verwijder het luchtfilterframe Maak het luchtfilter schoon met een zacht kwastje met perslucht of met een stofzuiger die op een lage sta...

Reviews: