
EN
28
Subindex 8d
Subindex 8d refers to the Input for rated frequency (P141). It describes from which source the frequency
inverter receives the setpoint.
Value
Selection inverter
805c
hex
Digital inputs
805d
hex
SycoDrive
805e
hex
CAN
805f
hex
Analog input
NOTE: See also Operating Manual Operating Software SycoDrive for HF Inverters e
@
syDrive 4624, 4625, 4626.
Index
(hex)
Name
Object type
Data type
Access
PDO
mapping
Default
3000:8d
input_f-soll
Variable
Unsigned16
rw
no
Subindex 92
Subindex 92 refers to the Direction of rotation (P146).
The direction of rotation is determined by the current setting of the parameter / object "Direction of rotation"
(P146 / 0x3000:92) in connection with the setpoint value via CAN (0x6042 vl_target_velocity). A positive sign of
vl_target_velocity (0x6042) leads to the direction of rotation set via PC or digital inputs, a negative sign to the
corresponding opposite direction of rotation.
Value
Selection inverter
8062
hex
Counter-clockwise
8063
hex
Clockwise
8064
hex
Digital input
NOTE: See also Operating Manual Operating Software SycoDrive for HF Inverters e
@
syDrive 4624, 4625, 4626.
Index
(hex)
Name
Object type
Data type
Access
PDO
mapping
Default
3000:92
drehrichtung
Variable
Unsigned16
rw
no
Subindex 95
Subindex
95 refers to the motor parameter sets saved in the inverter (M1…M16). Each bit represents a
memory location for a motor parameter set, where bit 0 (LSB) represents parameter set 1 (M1).
Bit
15
Bit
14
Bit
13
Bit
12
Bit
11
Bit
10
Bit
9
Bit
8
Bit
7
Bit
6
Bit
5
Bit
4
Bit
3
Bit
2
Bit
1
Bit
0
Mx
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
1
1
X
X
X
X
X
X
X
X
X
X
X
X
X
X
1
X
2
X
X
X
X
X
X
X
X
X
X
X
X
X
1
X
X
3
X
X
X
X
X
X
X
X
X
X
X
X
1
X
X
X
4
X
X
X
X
X
X
X
X
X
X
X
1
X
X
X
X
5
X
X
X
X
X
X
X
X
X
X
1
X
X
X
X
X
6
X
X
X
X
X
X
X
X
X
1
X
X
X
X
X
X
7
X
X
X
X
X
X
X
X
1
X
X
X
X
X
X
X
8
X
X
X
X
X
X
X
1
X
X
X
X
X
X
X
X
9
X
X
X
X
X
X
1
X
X
X
X
X
X
X
X
X
10
X
X
X
X
X
1
X
X
X
X
X
X
X
X
X
X
11
X
X
X
X
1
X
X
X
X
X
X
X
X
X
X
X
12
X
X
X
1
X
X
X
X
X
X
X
X
X
X
X
X
13
X
X
1
X
X
X
X
X
X
X
X
X
X
X
X
X
14
X
1
X
X
X
X
X
X
X
X
X
X
X
X
X
X
15
1
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
16
NOTE: See also Operating Manual Operating Software SycoDrive for HF Inverters e
@
syDrive 4624, 4625, 4626.
Index
(hex)
Name
Object type
Data type
Access
PDO
mapping
Default
3000:95
MotorMemory.all
Variable
Unsigned16
ro
optional,
TPDO only