Commissioning
Page 20/40
Installation and starting instruction manual
SYCLOPE TRACE’O
®
7)
Connections of the analogue outputs (IA1 and IA2
The analogue outputs of the
SYCLOPE TRACE’O
®
controller are used to forward information to a
central unit or to control a dosing unit by means of a signal of 0/4…20 mA.
The analogue outputs of the
SYCLOPE TRACE’O
®
controller are fully configurable. You can therefore
assign an output to any measured parameter and use it for regulation or transfer operations.
8)
Connection of the remote control input (CAD)
The
SYCLOPE ODISEA
®
controller has a remote control input “CAD” which stops the regulation
units. This input is an open/closed contact input used in a subservient manner to the main circulation
pump of the pool filtration system.
It is compulsory to slave your
SYCLOPE ODISEA
®
controller to the switch of the filter
motor to prevent incidents caused by overloads!
The remote control input is designed to receive a NO contact (normally open).