background image

MHDBT-88P 

SY Electronics Ltd, Unit 7, Worrall Street, Salford, Greater Manchester, M5 4TH, United Kingdom 

Tel: +44 (0) 161 868 3450     

      Fax: +44 (0) 161 868 3459     

             

www.sy.co.uk 

Installation Guide

 

 

8 x 8 HDMI Matrix Switcher 

with 

HDBT PoC Outputs 

 

 

 

 

 

8 HDMI in to 8 HDBT + 4 mirrored HDMI out 

 

 

Summary of Contents for MHDBT-88P

Page 1: ...t 7 Worrall Street Salford Greater Manchester M5 4TH United Kingdom Tel 44 0 161 868 3450 Fax 44 0 161 868 3459 www sy co uk Installation Guide 8 x 8 HDMI Matrix Switcher with HDBT PoC Outputs 8 HDMI...

Page 2: ...orts PoC providing power for all the receivers connected to the HDBT outputs x Supports multiple control methods front panel RS232 IR and optional TCP IP control x Multiple EDID management x LCD shows...

Page 3: ...HDMI output devices for local monitoring HDBT Output extension ports works with HDBT receivers for example SY HDBT 70PR SY HDBT 100R RS232 Serial port for controlling the matrix IR ALL IN IR control...

Page 4: ...nal can be transmitted bi directionally 7 The MHDBT 88P can be controlled by its built in IR receiver or through the IR EYE port by connecting with external IR receiver The IR signal can also be trans...

Page 5: ...ut 4 All input ports copy the EDID data from one output port Operation EDID ALL OUTPUT ENTER Example All input ports read EDID data from output 4 Predefined EDID Settings There are four types of embed...

Page 6: ...is not Check the output resolution Use button to check all the 8 output resolutions Output Check Press any output button to check its corresponding input Example To check which input is connected to o...

Page 7: ...t channel number of the MHDBT 88P There must be an HDBT receiver with an IR detector connected Example Send the RS232 command 3R2 to transfer the received IR signal from zone 2 to IR OUT port 3 Note W...

Page 8: ...BT receiver which must have an IR transmitter connected When the IR receiver is connected to IR ALL IN port the IR signal is simultaneously sent to all 8 HDBT receivers each of which must have an IR t...

Page 9: ...ideo player the HDBT 8x8 matrix etc from the remote location In this case the IR signal received from the HDBT receiver will be transmitted to the corresponding IR OUT port of the MHDBT 88P as shown b...

Page 10: ...like1 1 1 2 8 7 8 8 1 1 and so on The switching interval is 2 seconds Undo To cancel the previous operation x All Transfer signals from the input channel x to all output channels All Transfer all inpu...

Page 11: ...M N O or P HDBT PWOFF commands For items c or d send this command it will be saved by the matrix switcher and not sent to the corresponding HDBT receiver The command functions will be sent after the m...

Page 12: ...ent by port 4 when PWON 9955 Check the command sent by port 5 when PWON 9956 Check the command sent by port 6 when PWON 9957 Check the command sent by port 7 when PWON 9958 Check the command sent by p...

Page 13: ...MHDBT 88P sy co uk 13 4 Type the command carefully it is case sensitive...

Page 14: ...32 control software and with the right communication settings you are able to control the MHDBT 88P Local Control of the MHDBT 88P Control the MHDBT 88P from local Control the MHDBT 88P from Remote Lo...

Page 15: ...Device through 9 pin female RS232 port Control 3rd Party Device from Remote Location By connecting the 3 way captive screw RS232 port on the HDBT receiver to a PC or the controlled device the RS232 si...

Page 16: ...ID data and manual EDID management Audio Output Stereo Analogue and Digital HDMI Control Interfaces RS232 and IP Power Supply 110V 240V AC 50 60 Hz Power Consumption Fully Loaded 117 8 W Unloaded 54 4...

Page 17: ...has sufficient power to supply the device it is connected to 2 Do not operate either of these products outside the specified temperature and humidity range given in the above specifications 3 Ensure t...

Reviews: