1.6 End of Measuring Range
Enter the respective value of the measuring
range end.
With set the value to 1.0 to start enter the
numbers of the measuring range, with
transfer the entry and leave the menu level.
1.7 Filter Value
Adjustable damping for the
display
in
seconds.
Range: 0.1 ... 999.9 s
With set the value to 0.0 to start enter the
numbers of the measuring range, with
transfer the entry and leave the menu level.
2. ALARM
Effect onto the relay
With and select according to your
significance, with leave the menu without
any change, with transfer the entry and
switch to a deeper menu level.
2.1 Type of Alarm
None / min / max.
With and select according to your
significance, with leave the menu without
any change, with transfer the entry and
switch to a deeper menu level.
2.2 Value of Alarm
Threshold value.
Range: -10 ... 110 % of the measuring range
in phys. units.
With leave the menu without any change,
with transfer the entry and leave the
menu level.
C
8
Meas. Range
7 8
9
Set high
4 5
6
10.0
kg/h
1 2 3
C
0
8
C
8
Meas. Range
7 8
9
Filter
4 5
6
1.0
s
1 2 3
C
0
8
C
8
C
8
£
¤
Alarm 1
£
Alarm Type
¤
low alarm
C
8
C
8
£
¤
Alarm
7 8 9
Alarm Value
4 5 6
1.0
kg/h
1 2 3
C
0
8
2. Alarm
£
2.1 Type
low alarm
¤
2.2 Value
1.0
2.3 Delay
0.1 s
C
2.4 Hysteresis
1.0 %
8
q