TRACKER
3442.500.02
Version 2.1
Page 13
5 PROPERTIES
5.1 TRACKER connections
A
START OUT
(Tuchel 4pMT)
2 normally open contacts to connect the starting gate and the
timing device.
Pinning:
1: GND
2: Start Out (+)
3: Start Out (-)
E: +12VDC
C
ON / OFF
switch
O: switched OFF
I : switched ON
D
Volume control
and switch
Turn it to switch on the sound and then to control the volume of
the sounds (beep).
E
Tripod fixation
To fix the Tracker on the tripod, allowing to turn it.
F
DATA
(Tuchel 7pFT)
[RS422]
Data connection to the main judge controller.
Pinning: 1: START OUT -
2: START OUT +
3: Tx-
4: Tx+
5: Rx-
6: Rx+
7: Not connected
G
POWER
(Tuchel 3pMT)
1: L (115 - 230VAC)
3: N (115 - 230VAC)
E: GND