OMEGA Scan'O'Vision MYRIA
Version 1.0
3503.502.02
Page 5
2.3
Power ON / Power OFF
As soon the camera is powered by the Ethernet cable (PoE), the camera will boot; it takes about
40 seconds to be in operation. There is no ON/OFF switch.
When the power is removed (Ethernet cable unplugged or PoE injector switched off), the camera
will turn off, losing its time base (synchronisation).
2.4
Indicators
On the rear panel, different LEDs indicate the state of the camera:
LED Name [color]
Description
Inclinometer left [yellow]
If blinking: see from rear, the left side of the camera is too
high. The faster the LED blinks, the closer the sensor is to
vertical.*
WiFi status [blue]
ON: WiFi enabled.
Ethernet status [green]
Flashing when Ethernet activity.
General status [green]
ON: µC powered, initialization in progress or freeze.
Fast blinking (~5Hz): µC working, time based not sync.
Slow blinking (~1Hz): µC working, time base sync.
PoE status [green]
ON: AT type 2 compliant PSE detected.
Inclinometer Right [yellow]
If blinking: see from rear, the right side of the camera is too
high. The faster the LED blinks, the closer the sensor is to
vertical.*
*: sensor is vertical when
and
are switched ON.