background image

 

 

Page 10

 

3503.502.02 

Version 1.0 

3.4.3 

Synchronization Window 

The logo representing the synchronization status has a different signification. 

 

OSV-STAR 

OSV MYRIA 

 

 

Sync  not  done  or  sync  done 
automatically with PC time 

Sync not done or Manual sync done or sync 
done automatically with PC time 

 

 

Sync  done  (manual  or  with  start 
pulse) 

Sync done with start pulse 

 

3.4.4 

Camera settings 

White balance 
To do the automatic white balance: 

 

In  Camera  settings  active  the  matrix  view  (  
should be displayed). 

 

Enable the horizontal references (  should be 
displayed). 

 

With  the  left  mouse  button,  draw  a  rectangle 
in the live image where white should be. 

 

Click on the Auto-Adjust button. 

 

Zoom in matrix 
To  change  the  location  of  one  of  the  three  zoom 
square:  

 

In  Camera  settings  active  the  matrix  view  (  
should be displayed). 

 

Disable the horizontal references (  should be 
displayed). 

 

Click on one of the three zoom (at the right of 
the matrix view) to select it. 

 

Click  in  the  matrix  view  to  assign  the  center 
location  of  the  vertical  position  (horizontal 
position is automatically fixed). 

 

Choice of timing line in matrix 
The vertical line (timing line) can be move by using < and > buttons. The | button will replace it in 
the center. When the horizontal references are enabled (  is displayed), you can also do SHIFT-
right-click in the matrix image to place the timing line. 
 
Active Link 
Active Link+ is not available with MYRIA software. Instead you should:  

 

Open the race or do Fast Open on both instances. 

 

If the race is not "seen", wait until the start occurs - that should solve the problem. 

 

When race is "seen" on both instances, press "Active link" button on main instance

 
 

 

Summary of Contents for MYRIA 10

Page 1: ... 488 36 11 P O Box 138 Rue de l Envers 1 info swisstiming com CH 2606 Corgémont Switzerland www swisstiming com OMEGA Scan O Vision MYRIA PHOTO FINISH CAMERA USER S MANUAL 3503 502 02 l Version 1 0 l October 2017 MYRIA 10 MYRIA 16 ...

Page 2: ...ure to maintain a sufficient security distance from the public Documentation Updates Swiss Timing LTD reserves the right to make improvements in the products described in this documentation at any time without prior notice Furthermore Swiss Timing LTD reserves the right to revise this documentation in its content at any time and without any obligation to notify any person or organization of such r...

Page 3: ... 2 3 Power ON Power OFF 5 2 4 Indicators 5 3 SOFTWARE 6 3 1 Computer specification 6 3 2 Software installation 6 3 3 Network card configuration 8 3 4 Software use 9 3 4 1 Information about camera 9 3 4 2 Test Window 9 3 4 3 Synchronization Window 10 3 4 4 Camera settings 10 4 TECHNICAL SPECIFICATIONS 11 4 1 General specification 11 4 2 Electric specification 11 4 3 Certification 11 4 4 Connections...

Page 4: ......

Page 5: ...and its connections It also contains information to install the software and driver on your computer and specific software function for this camera The complete use of the software is described in the manual 3434 501 A 10x MYRIA 10 or 16x MYRIA 16 optical zoom lens is integrated in the camera housing It is fully remote controlled zoom iris and focus It allows setting the camera in almost any locat...

Page 6: ...iew 1 2 Definitions The camera is typically supplied with a support permitting the setting of its position according to 4 axes here are the definitions used in this manual Translation Horizontal displacement perpendicular to the finish line Pan Rotation in the horizontal plane Tilt Rotation in the vertical plane in the axis of the finish line Swivel Rotation in the vertical plane perpendicular to ...

Page 7: ... prevent the competitors in the foreground masking another Centre the tripod on the extension of the finish line If it is equipped with a spirit level align the bubble precisely in the middle of the reference mark Then slowly tighten all screws checking bubble does not move For a better stability spread the legs as far apart as possible and do not raise the central extension tube On the tripod fir...

Page 8: ... do manual recording of images it is recommended to connect a pushbutton option 2872 003 on the FINISH bananas Connect the 10m network cable Ethernet Gigabit 9051 1315 between the Ethernet connector on the camera and the PoE connector of the PoE injector power supply Connect the 2m network cable Ethernet Gigabit 9051 1317 between the LAN connector of the PoE injector and the computer Connect the p...

Page 9: ...escription Inclinometer left yellow If blinking see from rear the left side of the camera is too high The faster the LED blinks the closer the sensor is to vertical WiFi status blue ON WiFi enabled Ethernet status green Flashing when Ethernet activity General status green ON µC powered initialization in progress or freeze Fast blinking 5Hz µC working time based not sync Slow blinking 1Hz µC workin...

Page 10: ...work for computers connection 2nd network adapter different from camera 1Gb s recommended For example USB3 Ethernet adapter DeLock 62121 1Gb s recommended Various USB port for software installation USB port for software installation 3 2 Software installation 1 Install the software available on the delivered support Installer will also install PLEORA eBUS SDK 64 bit driver for camera Ethernet conne...

Page 11: ...rom the list of All Programs Pleora Technologies Inc eBUS SDK 4 Click on the Advenced button of GiGE VISION part 5 In the scroll list select the network adapter where the camera is connected Ensure that check boxes eBUS Universal Pro for Ethernet and Jumbo Packet are checked 6 Close the windows ...

Page 12: ... on the Properties button Click on Use the following IP address and enter data as in the picture below Note IP address is 192 168 2 100 for OSV MYRIA connection and 192 168 0 100 for OSV STAR connection Click on the OK button of this window and then on the OK button of the previous Connection Properties window It is also recommended to fix the transmission speed to 1Gb s between the computer and t...

Page 13: ...nd OSV MYRIA images with any OSV7 software configuration The complete use of the software is described in the manual 3434 501 available in the Documentation sub directory Following are some change related to MYRIA camera 3 4 1 Information about cameraWith Help About Hardware menu you can get a lot of information about the camera for example its inclination or the temperature inside the camera hott...

Page 14: ...of the three zoom square In Camera settings active the matrix view should be displayed Disable the horizontal references should be displayed Click on one of the three zoom at the right of the matrix view to select it Click in the matrix view to assign the center location of the vertical position horizontal position is automatically fixed Choice of timing line in matrix The vertical line timing lin...

Page 15: ...2m Zoom Aperture Focus MYRIA 16 16x 4 2o to 61 3o F1 8 1 0m Zoom Aperture Focus 4 2 Electric specification Condition Min Typ Max Unit Power supply PoE injector side up to 100m cable 48 56 V Power supply On camera input 42 56 V Power consumption 10m cable 14 15 W Power consumption 100m cable 19 21 W 4 3 Certification According to IEC 61326 1 2014 Class A equipment IEC 61000 4 2 2009 Electrostatic d...

Page 16: ...nal 1 TxRx A and VDC1 2 TxRx A and VDC1 3 TxRx B and VDC1 4 TxRx C and VDC2 5 TxRx C and VDC2 6 TxRx B and VDC1 7 TxRx D and VDC2 8 TxRx D and VDC2 I O Matching cable connector Binder serie 723 09 0129 70 12 Pin nbr Signal View A Not connected B Ready 1 C Finish 2 D Finish 2 E Start 2 F Start 2 G Rx RS232 input 3 H GND J 5VDC output max 100mA K PPS input L Ready 1 M Tx RS232 output 3 Notes 1 Outpu...

Page 17: ...is around 20 C 5 2 Maintenance Never touch the glass in the front of the camera with your fingers After use please always replace the protection cap It is recommended to clean the glass in the front of the camera regularly with a photographic link free cloth 6 APPENDICE 6 1 Index figures Figure 1 MYRIA front view 2 Figure 2 MYRIA bottom view 2 6 2 Version history Version Date Modifications since l...

Page 18: ......

Page 19: ...Swiss Timing LTD Phone 41 32 488 36 11 P O Box 138 Rue de l Envers 1 info swisstiming com CH 2606 Corgémont Switzerland www swisstiming com ...

Reviews: