15
14
Logo mat
Balance Plate
Logo mat
Force Plate
Mounting rail
Wood stud
Board
Turf
Minimum 3 cm/1.2 in
gap between the sensor
plates and the wood
construction.
Ensure space to connect USB
cable, create a cut-out in the
floor boards if necessary.
Same height as
sensor
logo mat.
Side view
Top view
Board cut-out for USB chord
W
ood stud
W
ood stud
Board
7,9 cm /
3.11’’
1 cm /
0.4’’
ø
1
ø
1
ø
1
: Mounting holes. Use screws to fix
mounting rail to the floor.
Insert two of the feet into the mounting rail.
Part 3
Flooring & Specifications
Part 3