Important information

General ventilation in the 

kitchen

The general ventilation in the 

kitchen must not be routed via the 

cooker hood if the hood's duct is 

connected to the ventilation unit's 

separate extract air duct. The ven-

tilation unit's separate extract air 

duct runs past the heat exchanger 

and the use of this duct will have 

an effect on the annual efficiency 

of the ventilation unit.

Commissioning

Installation, adjustment and com-

missioning must be carried out in 

accordance with local directives. 

The entire ventilation of the  

residence must be taken into con-

sideration when adjusting the 

cooker hood’s air flow.
The cooker hood must only be con-

nected to a chimney that conforms 

to the regulations. In high-rise blocks 

the permission of the property 

company is always required.

Safety clearance

The relative spacing between the 

cooker hood and the hob level 

should be at least: 400 mm (recom-

mendation 500 mm, electric cook-

er) 650 mm (gas hob).
Follow separate instructions from 

the local authorities or the cooker 

manufacturer. Always consult your 

local fire consultant prior to instal-

lation if the relative space is smaller 

than 500 mm between the cooker 

hood and the hob.

Replacement air

Ensure sufficient replacement air is 

taken into the room.
This applies especially if a fireplace 

is used as well as a cooker hood.

Service measures

The service measures that the user 

can carry out are limited to clean-

ing the surfaces of the appliance 

and the grease filter. 

!

This document is intended for everyone involved in the installation work or use of a Swegon 

CASA cooker hood. Read this Instructions for Use before you use the cooker hood. Save the 

Instructions for Use for future use. If you mislay the Instruction for Use, you can download a 

new copy from our website. 

The cooker hood is not designed to be used by children (below 8 years old) or by persons 

whose senses, physical or mental capacity or a lack of knowledge and experience limits safe 

use of the cooker hood. Such persons may use the cooker hood if supervised by a person 

who is responsible for their safety, or according to the instructions.

Never flambé under the cooker hood!

EC Declaration of Conformity

https://serviceportal.swegon.com/fi//docs/docH

Summary of Contents for CASA Smart Sensor

Page 1: ...P_Hoods_l u 2020 12 22 K SIKIRJA HANDBOK FI SE Blues Salsa Samba Tango Jazz Swegon CASA Smart H NDBOK HANDBOOK NO EN...

Page 2: ...or the cooker manufacturer Always consult your local fire consultant prior to instal lation if the relative space is smaller than 500 mm between the cooker hood and the hob Replacement air Ensure suf...

Page 3: ...sories 44 7 1 External control functions 44 7 2 Safera safety technology 44 7 3 Twist fan unit 44 7 4 ILVA transformer unit 44 7 5 Ext out relay for 230 V 44 8 Technical data 45 8 1 Capacity for captu...

Page 4: ...used for controlling ventilation units equipped with Smart control technology EC power roof ventilator Swegon CASA cooker hoods can be used to control a power roof ventilator equipped with an EC fan...

Page 5: ...on is balanced when the cooker hood is used as the excess extract air that passes via the hood causes negative pressure in the home Balancing occurs automatically when the cooker hood is connected to...

Page 6: ...on shows which mode is being set NOTE The fan speeds for the operating modes can only be set in the order low to high for example the Away mode speed cannot be higher than the Home mode speed Increase...

Page 7: ...ting is switched on and off with a button The factory default of the lighting output is 75 5 1 2 3 4 The lighting output can be regulated with a long press on the button the brightness then changes Pr...

Page 8: ...erial and manufacturing faults is limited to the repair or 7 Accessories POWER 24 VDC EXT OUT NO NO CONTROL max 30 V 5 A replacement of the defective product unless compulsory legislation states other...

Page 9: ...3141 3 2017 75 48 l s Odour capture Airflow rate l s according to EN13141 3 2017 75 48 l s 30 40 50 60 70 80 90 10 15 20 25 30 35 40 Odour capture Airflow rate l s according to EN13141 3 2017 75 51 l...

Page 10: ...0 10 100 Airflow rate l s Pressure drop Pa Salsa Airflow rate l s Pressure drop Pa LWA 20 LWA 30 LWA 40 LWA 50 1 10 100 10 100 Tango Airflow rate l s Pressure drop Pa LWA 20 LWA 30 LWA 40 LWA 50 1 10...

Page 11: ...20 40 60 80 100 120 140 160 180 200 15 20 25 30 35 40 45 50 55 60 65 70 75 80 Air flow rate l s Pressure differential Pa Air flow rate l s Pressure differential Pa Open holes in the damper 1 2 3 4 5 6...

Page 12: ...or EC power roof ventilator 0 10 VDC 4 Ext in control of damper and lighting with potential free contact signal 5 Ext out damper position signal normally open Connector in accessory bag POWER 24 VDC...

Page 13: ......

Page 14: ......

Reviews: