-13-

Setting Ring-back Tone

If allow ring-back tone, press the call button to call monitor, a ring-back call tone can be heard 

from door station.

There are 3 ring-back call tones, 

Ringing one time

,

Ringing continuously 

and

 No ring-back 

tone

Ringing one time is default, to change the setting, please follow the steps:

UNLOCK Indicator:ON

TALK Indicator:ON

Buzzer

Beep+, Beep

In standby mode, press 

KEY_SET

 button 

four 

times

.

UNLOCK Indicator:ON

TALK Indicator:ON

Buzzer

Beep+

Press 

KEY_1 

button to set 

the ring-back call tone ringing
one time.

UNLOCK Indicator:ON

TALK Indicator:ON

Buzzer

Beep, Beep

Press 

KEY_1 

button again

to set the ring-back call tone 
ringing continuously.

UNLOCK Indicator:ON

TALK Indicator:ON

Buzzer

Beep, Beep,Beep

Press 

KEY_1 

button again

and again to close ring-back
call tone.

Press 

KEY_1

• 

If setting mode has not been exited, you can change the ring-back tone by pressing KEY1 circularly.

• 

The 

LED_NAME

 indicator will blink all the time until exit out the setting mode.

• 

If without any operation in 10 seconds, it will exit out setting mode automatically.

• 

In this step,press 

KEY_SET

 button once to exit out the setting mode manually.

Summary of Contents for SVT-2 PC6

Page 1: ...SVT 2 Outdoor Station B User Manual SVT 2 Outdoor Station B 2W12120 Please read this user manual prior to installing the system and keep it well for future use Dan Smith ...

Page 2: ...ystem Wiring and Connections 4 5 1 Basic Connection 4 5 2 Electric Lock Connection 5 5 2 1 Door Lock Controlled with Internal Power 5 5 2 2 Door Lock Controlled with Dry Contact 5 5 3 Multi Outdoor Stations Connection 6 5 4 Multi Indoor Monitors Connection 7 5 4 1 Basic IN OUT Wiring Mode 7 5 4 2 With DBC 4 Wiring Mode 8 6 Setup Instructions 9 14 6 3 Power Supply 15 7 Cable Requirements 16 ...

Page 3: ...Motion Detector Connect Port 12 V GN D PI R L1L2PLS S Main Connect Port 11 10 9 1 3 4 8 7 6 5 12 13 2 1 Microphone 2 UNLOCK indicator 3 CALL indicator 4 Call button 5 Nameplate 6 Front panel 7 Speaker 8 Night view LED 9 Camera lens 10 Rain cover 11 Mounting hook 12 Connection port 13 Screw hole ...

Page 4: ... power output connect to the power input of locks only when using the door station to power the locks if using the external power supply for the locks the S will not be connected Power supply Power consumption Camera lens Lock Power supply Number of relay circuits Mounting Working temperature Protection Material Wiring Dimension DC 24V Standby 0 8W Working 3W Color CMOS 520TVL 1 4 camera 115º wide...

Page 5: ..._CLASS AcDbMLeader ACDB_MLEADER_CLASS 1 Connect the cable correctly 2 Dr l holes in the wall to match the size of screw stoppers then attach the rainy cover and main unit to the wall and the distance between the top of main unit and rain cover should be not less than 3mm 3 Install the name plat 4 Attach the front panel to the main unit 5 Use the special screwdriver and the screws to fix the pan ...

Page 6: ...external motion detector If the external motion detector is connected to the system following functions will be effec tive If detect someone passing by the door station can be activated operation to unlock or turn on light 12V Motion detector GND PIR BUS IM BUS DS L1 L2 PL S S ID 0 1 2 3 4 5 6 ON DIP L2 L1 DIP Switches SVT 2 PC6 AC 100 240VAC ...

Page 7: ...timed from Exit Button EB 5 The Unlock Mode must be set to 0 by default EB LOCK Jumper position on 2 3 1 2 3 L1 L2 PL S S 1 The external power supply must be used according to the lock 2 The inside relay contact is restricted to 230Vac 1A or 24Vdc 1A 3 The jumper must be taken off before connecting 4 Setup the Unlock Mode according to different lock types Power on to unlock type Unlock Mode 0 by d...

Page 8: ... door station ID 1 2nd door station ID 2 3rd door station ID 3 4th door station L1 L2 PL S S L1 L2 PL S S L1 L2 PL S S L1 L2 PL S S To monitors Max 4 outdoor stations can be connected to the system Ensure to set the correct address for each outdoor station Refer to Page X for more details about the address setting of outdoor stations ...

Page 9: ... 7 5 4 1 Basic IN OUT Wiring Mode 5 4 Multiple Indoor Monitors Connection ID 0 Optional modules BUS IM BUS DS SVT 2 PC6 AC 100 240VAC SCU TPS ...

Page 10: ... 5 4 2 Using SVT 2 DBC 4 distributor device Wiring Mode DBC4A1 A B C D SVT 2 RCL SVT 2 DBC4 Impedance OFF ON switch Code 1 Code 2 Code 3 Code 4 ID 0 Optional modules SVT 2 BDU 85 260AC SVT 2 DPS SVT 2 PS5 ...

Page 11: ...g items Setting range Default value 1 Setting door station address 0 3 0 2 Setting door station calling mode Standard Group calling mode Standard calling mode 3 Setting camera resolution High Low High 4 Setting the unlock mode 0 opened 1 closed 0 opened 5 Setting the unlock time 01 to 99 seconds 1 seconds 6 Setting the nameplate illumination mode On Off Auto On 7 Setting night view LED illuminatio...

Page 12: ... Beep UNLOCK Indicator OFF TALK Indicator OFF Buzzer Beep Beep Beep UNLOCK Indicator OFF TALK Indicator OFF Buzzer Beep Beep Beep Beep ID 0 1st door station ID 1 2nd door station ID 2 3rd door station ID 3 4th door station Setting Door Station Calling Mode A Call buttonA Call all monitors in group address from 00 15 one of the monitor should be set to 00 Group calling mode UNLOCK Indicator OFF TAL...

Page 13: ...or OFF Buzzer Beep Beep In standby mode press KEY_SET button three times UNLOCK Indicator ON TALK Indicator OFF Buzzer Beep Beep Press and hold on KEY_2 button The time you holding on is the new unlock time When entering time delayed setting the buzzer sound one time every second The LED_NAME indicator will blink all the time until exit out the setting mode If without any operation in 10 seconds i...

Page 14: ...exit out setting mode automatically In this step press KEY_SET button twice to exit out the setting mode manually Setting Night View LED Illumination Mode There are 3 working modes for night view LED indicator Normally on Normally off and Auto Auto is default to change the setting please follow the steps UNLOCK Indicator ON TALK Indicator OFF Buzzer Beep Beep In standby mode press KEY_SET button t...

Page 15: ...s KEY_1 button to set the ring back call tone ringing one time UNLOCK Indicator ON TALK Indicator ON Buzzer Beep Beep Press KEY_1 button again to set the ring back call tone ringing continuously UNLOCK Indicator ON TALK Indicator ON Buzzer Beep Beep Beep Press KEY_1 button again and again to close ring back call tone Press KEY_1 If setting mode has not been exited you can change the ring back tone...

Page 16: ...de 9 8220 Code 20 8231 Code 31 8210 Code 10 8221 Code 21 For additional settings refer to the Indoor Monitor User Manual 6 2 DIP Switches Settings of Indoor Monitor There are 3 DIP switches in total Bits 1 and 2 are reserved and must be on the default position The Bit 3 is used to configure the position of each indoor monitor in the connection line It must be set to ON if the indoor monitor is in ...

Page 17: ...ors It must be used along with a SVT DPS device It supplies power for the outdoor stations indoor monitors and other accessories It supports up to 8 indoor monitors Input Voltage 100 240Vac Input Frequency 50 60Hz Rated Output Voltage DC 28V 2V Rated Output Current 1 5A Input Voltage 100 120VAC 2 5A 200 240VAC 1 5A Input Frequency 50 60 Hz Rated Output Voltage 24Vdc Rated Output Current 4 5A ...

Page 18: ...ductor must solder the ends 200 feet 60 meters 14 AWG Speaker Wire Stranded non shielded When Monitor quantity 16 328 feet 100 meters 260 feet 80 meters 393 feet 120 meters A B SVT 2 PC6 Cable Usage A B CAT5 cable 1 pair of wire per conductor must solder the ends 200 feet 60 meters 14 AWG Speaker Wire Stranded non shielded 131 feet 40 meters 260 feet 80 meters 196 feet 60 meters ...

Page 19: ... 17 ...

Page 20: ...The design and specifications of this user manual can be changed without any notification to the user All copyright and interpretation rights are reserved to SVT Innovations Inc ...

Reviews: