Mode of operation

SHR-12 K1 verifies coded radio frequency signals sent by corresponding transmitters and operates a relay output on receipt of a 
correct signal. The rated current for the relay is 10 A / 230 VAC maximum. All transmitters of the series SH-12 including the module CX-
12 T are suitable with SHR-12 K1.

It should be noted that for applications that could put human life at risk, by using radio connection there is always
present a potential hazard due to extraneous disturbances.
The Operating Instructions need to be followed at all times.

2

Safety Precautions

Ensure that the product is isolated from any power supply before opening. Opening and installation of the product 
must be performed only by a qualified electrician.

Further safety precautions

Every applicable regulations and standards have to be observed, in particular VDE0100, VDE0550/0551, VDE0700, VDE0711 and 
VDE0860. The use of solid cables for connection is recommended since terminal design does not incorporate stress relief. The 
product corresponds to Safety-Class II (without protective earth terminal) according to VDE0700, IEC335EN60335.

For commercial use, compliance must be made with the recommendations and instructions of the responsible regional/national 
authorities.

For use in public institutions, schools, clubs and do-it-yourself workshops the operation of this product has to be supervised by 
qualified personnel. 

We do not assume any warranty and liability for personal or material damages caused by incorrect application or by failure to follow 
these operating instructions. 

For reasons of safety and conformity (CE) it is not permitted to modify or change parts of the product.

Electrical devices should be out of reach of children. Please be extra careful if children are around.

Opening and installation of this product has to be performed by authorised electricians only.

If you have not the corresponding expertise, ask qualified specialists or workshop for installation and commissioning. This product 
and connected devices can be damaged as a result from inappropriate installation, connection or operation. Furthermore, this could
lead to other damages e.g. short circuit, fire or electric shock.

The product must not be installed or used in places where a risk of explosion may exist.

Do not touch antenna connectors with live parts.

The product should only be used in a case adequate for mains-voltage if applied! 

The Relay Board is a state-of-the-art product. However, there is a risk of danger if installation or operation is performed by 
unqualified personnel

If the relay contacts switch mains power supply, the electronics has to be operated in a corresponding installation casing.

Attention. Extreme danger!
When opening the product, live components may be touched. Isolate SHR-12 K1 from the mains power supply before
opening. Ensure that all connected devices and components are also disconnected from the mains-power supply.

3

System operating range

The system SH-12 is designed for a large operating range of many hundred meters. Walls including steel reinforced concrete can be 
penetrated. The maximum range can be achieved under optimum conditions and by line-of-sight contact between transmitter and 
receiver without disruption by external high frequency disturbances. 
The following are possible causes that could reduce range of operation:

Obstructing buildings, vegetation or other factors will substantially reduce the operating range.

The distance between the antenna and the operator’s body or other conducting objects (e.g. Earth) may influence the working 
range.

Background “electrical noise” could be relatively high so that the signal-to-noise-ratio may decease and therewith the operating 
range. Also other devices, with similar operating frequency, operated in the neighbourhood of the receiver may reduce the 
sensitivity.

Operating the receiver adjacent to badly shielded electronic components (e.g. PC’s) that can produce electromagnetic distortion, 
may severely reduce the range of operation and could result in intermittent operation.

Adjustable and open components should not be adjusted or modified. 

4

Description

SHR-12 K1 needs a power supply of 12….24V DC or 12 V AC. 

The SHR-12 K1 provides the choice of a key-function or a timer switching function (up to 60 minutes) as well as a steady switching 
function.

A channel with key-function can be set with the shortest timer setting (refer to attached table). The relay remains closed as long as 
the transmitter key stays activated.

For applications, where, for example, inductances produce signal glitches due to electromagnetic interference during the switching 
process (apparent relay bouncing), the timer setting can be increased in small steps. The resulting delays, which can be considered
as falling edge delays, avoid the undesirable bouncing of the relay contacts when short glitches occur.

Furthermore, the adjustable timer settings provide time-limited switching (falling edge delayed) of any number of devices.

4

 -

Summary of Contents for 01270.24

Page 1: ...utzleiteranschluss existiert nicht Schutzklasse II gem DIN 0700 IEC 335 EN 60335 In gewerblichen Einrichtungen sind die Unfallverh tungsvorschriften des Verbandes der gewerblichen Berufsgenossenschaft...

Page 2: ...higen Gegenst nden abgeschirmt wird ffnen Sie das Geh use durch L sen der 4 im Boden befindlichen Schrauben Da die Schaltung nun offen liegt ist darauf zu achten dass keine statischen Entladungen auf...

Page 3: ...laisfunktion vorgenommen Die Einschaltdauer bzw Abfallverz gerung kann mit den 6 Schaltern s Bild im Anhang ausgew hlt werden Tabelle im Anhang zeigt die m glichen Werte die werkseitige Voreinstellung...

Page 4: ...ains voltage if applied The Relay Board is a state of the art product However there is a risk of danger if installation or operation is performed by unqualified personnel If the relay contacts switch...

Page 5: ...transmitter with acknowledgement of the transmitter signal Press 1x short the LEARN ERASE button The light of the LED beside the button interrupts 1x every 2s Learn mode II Learn a single key with ac...

Page 6: ...ation ou le manque de respect des instructions en quel cas la garantie serait caduque La conception de l appareil r pond aux crit res de compatibilit lectromagn tique nationaux et europ ens Les docume...

Page 7: ...a commutation entra neraient des interruptions radio par des perturbations electromagn tiques rebonds apparents du relais le temps de minuterie peut tre augment en petites tapes Ces laps de temps cons...

Page 8: ...place d utiliser l metteur ou une touche on peut galement supprimer la liste compl te en appuyant nouveau sur la touche LEARN ERASE jusqu ce que la LED c t du bouton s arr te de clignoter environ 3 s...

Page 9: ...Bij materi le schade of verwondingen die door onvakkundig gebruik of niet naleving van de veiligheidsaanwijzingen ontstaan aanvaarden wij geen aansprakelijkheid In dergelijke gevallen vervalt elke ga...

Page 10: ...bekneld of anderszins beschadigd mogen worden Let bij het aanbrengen van de bedrijfsspanning altijd op de naleving van de technische gegevens Maximale voedingsspanning 24 V Hogere spanningen vernietig...

Page 11: ...aadloze signaal het relais bedraad moet worden ingeschakeld kan de positieve voedingsspanning via een knop behoort niet tot de standaardlevering op de aansluiting Ext ON worden aangesloten Bij AC voed...

Page 12: ...n Radio Equipment Directive RED 2011 65 EU Restriction of Hazardous Substances RoHS und dass die nachstehenden harmonisierten europ ischen Normen zur Anwendung gelangt sind and that the following harm...

Reviews: