5.3.10
Debouncing trigger signals
Bounces or glitches caused by a switch can be avoided by software within the
SVCam.
Fig.: 5-40: Bounces or glitches caused by a switch
Therefore the signal will not be accepted until it lasts at least a certain time.
>
Use the IO Assignment tool to place and enable the debouncer module in
between the “trigger” (Schmitt trigger) and the input source (e.g.: line 1).
The “DebouncDuration” register can be set in multiples of 15 ns (implement of sys-
tem clock), e.g. 66 666 ≈ 1 ms
Fig.: 5-41: Debouncer between the trigger source and trigger