5.2.8
Read-out control
Read-out control defines a delay between exposure and data transfer. Read-out
control is used to program a delay value (time) for the readout from the sensor.
With more than one camera connected to a single computer, image acquisition
and rendering can cause conflicts for data transfer, on CPU or bus system.
Fig.: 5-27: Illustration of physical data stream in time
5.2.9
Temperature sensor
A temperature sensor is installed on the main board of the camera. To avoid over-
heating, the temperature is constantly monitored and read. Besides software mon-
itoring, the camera indicates high temperature by a red flashing LED (see flashing
LED codes).
5.2.10
System clock frequency
Default system clock frequency in almost every SVCam is set to 66.6 MHz. To
validate your system frequency refer to: specifications.
Using the system clock as reference of time, time settings can only be made in
steps. In this example, the transfer rate is 66.7 MHz, thus resulting in steps of
15 ns.
INFO
Use multiples of 15 ns to write durations into camera memory.
5 Feature description
63
Summary of Contents for SHR 10GigE
Page 1: ...Manual SHR 10GigE shr411 shr461 ...
Page 18: ...Fig 3 3 Firmware update 3 Getting started 18 ...
Page 30: ...Fig 5 4 Original image Fig 5 5 Horizontal flip 5 Feature description 30 ...
Page 37: ...5 Feature description 37 ...
Page 75: ...Fig 5 31 Example 25 PWM load Fig 5 32 Example 50 PWM load 5 Feature description 75 ...
Page 76: ...Fig 5 33 Example 75 PWM load The PWM module Fig 5 34 The PWM module 5 Feature description 76 ...
Page 92: ...6 2 shr411XGE 6 Dimensions 92 ...
Page 93: ...6 Dimensions 93 ...
Page 94: ...6 Dimensions 94 ...
Page 95: ...6 3 shr461XGE 6 Dimensions 95 ...
Page 96: ...6 Dimensions 96 ...
Page 97: ...6 Dimensions 97 ...