USER’S MANUAL

3. PACKAGE INCLUDES

1) UPS — 1 pcs
2) Power cord — 1 pcs
3) Power cord for load connection — 1 pcs
4) RS232 cable — 1 pcs
5) Software CD — 1 pcs
6) Instruction manual — 1 pcs
7) RJ11 Phone Jack Cable — 1 pcs
8) Reserved fuse — 1 pcs
9) Warranty card — 1 pcs

Notice: 

Power cord  is built in for model POWER SMART L 2000, for POWER SMART L 3000 power cord will be optional. You must use

power cord with each core diameter not less than 1,5 mm

2

.

4. THE MAIN FEATURES

!

High performance of conversion.

!

Wide range input voltage.

!

Full digital microprocessor control.

!

Pure sine wave output.

!

User’s adjustable Output DIP switches allow you to select an accommodate Output voltage for your critical device. 

!

Cold start function (DC power on).

!

Circuit Breaker for protecting the over current from the incoming AC utility.

!

Smart communication port (True RS-232).

!

Short Circuit and overload protection.

!

Advanced Input PFC control guarantees the PF performance and maximum energy efficiency.

!

SNMP adapter slot represents the advanced upgrade solution to achieve direct power management via internet world-wide. 

!

Additional sockets for connection of external batteries.

!

Automatical choosing of the optimal cooling mode.

5. SERVICE AND STORAGE

Cleaning

Before cleaning, turn off the switch of the UPS. Unplug the UPS from the power outlet. Also unplug the battery cable for the long back up
time model.
Clean all surfaces with a soft, lint-free cloth that you have dampened in a mild solution of detergent and water. The cloth must not be too
wet.

Warning

Never spill water or cleaning fluid inside the unit. Should this happen accidentally, call your maintenance authority immediately.

Do not use scouring pads, steel wool, harsh chemical agents, or anything that can damage the surface of the unit. 

Storage

If you plan to store the UPS, there is a risk that the battery might discharge to the point where is permanently discharged. To prevent this
from happening, follow these steps before storing the UPS:
a. Fully charge the battery before storing the UPS.
b. Recharge the battery for 24 hours at intervals not greater that 3 months.

14

Summary of Contents for SMART L 1000

Page 1: ...smart L 1000 2000 3000 On line SMART L 1000 SMART L 2000 SMART L 3000...

Page 2: ...SVEN Sven Company Ltd 2007 1 1 V 1 1 http www sven ru 2...

Page 3: ...SMART L 1000 2000 3000 1 4 2 4 3 4 4 On line Smart L 4 5 4 6 5 6 1 Smart L 5 6 2 Smart L 6 7 7 7 1 7 7 2 7 7 3 7 7 4 8 8 8 9 8 10 9 3...

Page 4: ...On line 2 3 1 1 2 1 3 1 4 1 5 1 6 1 7 RJ 11 1 8 1 9 1 1 POWER SMART L 2000 POWER SMART L 3000 POWER SMART L 3000 1 5 2 2 POWER SMART L 2000 2 POWER SMART L 3000 3 http www sven ru 4 ON LINE SMART L DC...

Page 5: ...6 6 1 Smart L a Power 220 15 20 UTILITY Power 1 INVERTER DC Power 1 15 20 INVERTER Power 1 b TEST OK TEST SILENCE 10 c TEST SILENCE 1 2 10 3 5 a b c d e g i f h a b c d e g i f h a b c d e g i f h Sm...

Page 6: ...75 6 75 h BATTERY LOW 1 2 TEST SILENCE 50 6 7 50 i OVER LOAD 1 2 TEST SILENCE 25 6 7 8 25 6 2 Smart L a IEC 320 Power Smart L 1000 2000 b Power Smart L 1000 2000 Power Smart L 3000 c 6 a a a d c c g b...

Page 7: ...Smart L 3000 2 Power Smart L 3000 e SNMP SLOT SNMP SNMP f DB9 DB9 RS 232 Upsilon 2000 g RJ 11 RJ 45 h DIP DIP SW1 SW4 220 DIP 7 7 1 Smart L 3000 7 2 8 7 3 OVER LOAD 0 7 0 8 0 7 0 8 0 8 0 7 0 8 0 9 1...

Page 8: ...7 4 OVER LOAD 8 9 8 1 2 3 1 e 2 3 1 2 1 2 1 2 3 1 8 2 3 FAULT 2 100 125 2 125...

Page 9: ...1000 Smart L 2000 Smart L 3000 1000 700 2000 1400 3000 2100 RISC DB9 SNMP RS 232 Windows 95 98 9X M NT 2000 XP Windows server 2003 Novell Netware Linux FreeBSD 45 1 IEC 320 IEC 320 3 1 IEC 320 3 2 2...

Page 10: ...8 200 220 230 240 3 110 110 120 Bypass 60 120 150 Bypass 10 150 Bypass 200 220 230 240 1 0 5 3 110 110 125 Shutdown 60 120 150 Shutdown 10 150 Shutdown 83 0 On Line 8 20 7 17 8 19 12 7 3 12 7 6 12 7 8...

Page 11: ...ruptible Power Supply SMART L 1000 SMART L 2000 SMART L 3000 Please read this operation manual before using the unit and retain this operation manual in safe place for future reference Eng SMART L 100...

Page 12: ...authority to operate the equipment UL WARNING STATEMENT See the Safety Instructions and Installation section in page 12 Technical support http www sven ru TABLE OF CONTENTS 1 Introduction 13 2 Safety...

Page 13: ...vice center for battery replacement or disposal Intended for installation in a controlled environment Refer to manual for environmental conditions When replacing batteries use the same number and type...

Page 14: ...efficiency SNMP adapter slot represents the advanced upgrade solution to achieve direct power management via internet world wide Additional sockets for connection of external batteries Automatical cho...

Page 15: ...ss mode and vice versa c To illustrate the percentage of output load level at AC Mode and the battery energy level at Backup Mode by pressing the button d Fault LED Red LED lights up if UPS is faulty...

Page 16: ...l feature used for SNMP card f Com Port RS 232 This is an interface to send signals to and receive signals from the computer g RJ11 RJ45 Jack This is to offer you a modem internet RJ11 and 10 Base T N...

Page 17: ...when Utility is abnormal f Re connect the input power cord of the UPS to wall receptacle then connect the power cord of your device to the output receptacle of the UPS g Turn on the Main switch on th...

Page 18: ...n If not your output load has probably been shorted Otherwise call for service Specifications Model Smart L 1000 Smart L 2000 Smart L 3000 Maximum load 1000 VA 700 W 2000 VA 1400 W 3000 VA 2100 W Proc...

Page 19: ...00 Output Battery Operation Voltage 200 220 230 240 V Frequency 1 Free Running Frequency Stability 0 5 Hz Wave Form Sine wave Voltage T H D 3 no load to full load Transient Response 10 R Load 0 to100...

Page 20: ......

Reviews: