(30)
Electrical connection
- NOTE! The electrical connection should be made as a fixed installation and must be made by a qualified electrician.
- The electrical connection is made from the mains to the electric box via an all pole breaker connection with 3 mm break distance.
- An earthed power breaker with a max 30mA release current is a necessity. The installation shall be completed to zonal
requirements.
- NB: Check the earth fault breaker function regularly.
- The rated data for the massage tub is displayed on the type plate. The type plate is located on the massage tub's electronic box.
- The product is prepared for potential equalization. The potential equalisation conductor should be
connected to the massage tub's potential equalisation clamp. The clamp is marked with the symbol .
- Parts with conductive components must be installed out of reach of people bathing (except safety parts with extra low voltage of
max. 12 V).
- Parts containing electronic components (except remote control/ control device) should be positioned or fixed so that they
cannot fall into the tub.
The massage tub is supplied with a mains lead (7G1.5 mm²) approximately 2 metres long. The mains lead must not be shortened,
otherwise it will be difficult to perform servicing and maintenance after the installation is completed. The mains lead should be left
free along its whole length, to prevent it being damaged if the massage tub is pulled or lifted out for service or maintenance. The
mains lead should be positioned so that it cannot be subjected to abnormal water exposure. The mains lead may not be rolled up
or otherwise insulated.
Colour codes, mains lead:
- Yellow/Green conductor: PE (protective earthing)
- Black conductor marked 1: N3 (Neutral conductor 3)
(not used)
- Black conductor marked 2: N2 (Neutral conductor 2)
- Black conductor marked 3: N1 (Neutral conductor 1)
- Black conductor marked 4: L1 (Phase conductor 1)
- Black conductor marked 5: L2 (Phase conductor 2)
- Black conductor marked 6: L3 (Phase conductor 3)
(not used)
See wiring diagram for connection to the permanent wiring.
Wiring diagram
GB