6-18
ELECTRICAL SYSTEM
Remove the trunk. (
5-4)
Disconnect the generator coupler
1
.
Connect the multi circuit tester with the peak volt adaptor as
follows.
Brown (
-
Probe) – White (
+
Probe)
Measure the pickup coil peak voltage in the same manner as on
the CDI unit coupler.
09900-25008: Multi circuit tester set
Tester knob indication: Voltage ( )
Pickup coil peak voltage: More than 5.0 V
If the peak voltage on the generator coupler is within specifica-
tion, but on the CDI unit coupler is not within specification, re-
place the wire harness with a new one. If both peak voltages are
out of specification, replace the pickup coil with a new one.
+
Y
/
W
W
/
R
Br
W
-
Gererator
Peak volt
adaptor
1
PICKUP COIL RESISTANCE
Remove the trunk. (
5-4)
Disconnect the generator coupler
1
.
Measure the resistance between the lead wires using the multi
circuit tester. If the resistance is not within the specified value,
the pickup coil must be replaced.
09900-25008: Multi circuit tester set
Tester knob indication: Resistance (
Ω
Ω
Ω
Ω
Ω
)
Pickup coil resistance: 120 – 250
Ω
Ω
Ω
Ω
Ω
(White – Brown)