Left turning time meet, R6 start, R7 is off.
Right turning time meet, R7 start, R6 is off.
Egg turning cycle times:
R6 start once+R7 start once as a cycle, when egg turning times=U14, stop turning.
Set U14=0, keep turning.
Air exchange control(R5)
Air exchange control mode:(U20=0)
When system running time meet
【
Air exchange period time(R5)
】
U22, start air exchange relay. Air exchange time meet
【
Air exchange
time(R5)
】
U24, air exchange relay is off.
Air exchange control mode+temperature and humidity over limit protection mode(U20=1)
No temperature/humidity over limit warning, controller work at air exchange mode.
When temperature/humidity over limit warning, high temp. Or high humidity air exchange relay work. When no warning, controller
back to air exchange control mode.
Air exchange mode+temperature over limit protection mode:(U20=2)
No temperature over limit warning, work at air exchange mode.
When temperature over limit warning, high temperature air exchange relay work. When no warning, controller back to air exchange
control mode.
Air exchange mode+humidity over limit protection mode:(U20=3)
No humidity over limit warning, work at air exchange mode.
When humidity over limit warning, high humidity air exchange relay work. When no warning, controller back to air exchange control
mode.
Lighting control(R4)
Lighting control mode(U30=0): press
, light on/off.
Time switch mode(U30=1):Time period(U32), R4 off. Timer time(U34), R4 is on.
Temperature and humidity over limit protection mode(U30=2):If temperature or humidity over limit warning, high temperature or high
humidity, R4 is on, when warning stop, R4 is off.
Temperature over limit protection mode(U30=3): If temperature over limit warning, high temperature, R4 is on, when warning stop, R4
is off.
Humidity over limit protection mode(U30=4): If humidity over limit warning, high humidity, R4 is on, when warning stop, R4 is off.
Warning output control(R8, R9)
Warning output mode(U40=0):
Warning node output: R8: Close when failure, open when no failure. R9 Open when failure, closed when no failure.
When temperature or humidity sensor failure, warning output is on, temperature or humidity control output off. Other outputs keep
working.
When temperature or humidity over limit, warning output start, all control outputs keep working.
Timer switch mode(U40=1): Timer period time(U42), R8 is off. Timer time(U44) R8 is on.
Temperature and humidity over limit protection mode(U40=2): temperature or humidity over limit protection, high temperature or high
humidity, R8 is on. When no alarm, R8 closed.
Temperature over limit protection(U40=3): temperature over limit protection, high temperature, R8 is on. When no alarm, R8 closed
Humidity over limit protection mode(U40=2): humidity over limit protection, high humidity, R8 is on. When no alarm, R8 closed.
Auto restart function: Power off, if power back, controller will back to work with previously setting parameters.
Incubation days cancel: keep press
for 3 seconds, days will be zero.
Factory setting: controller is on, press
and
at the same time for 3 seconds shows
『
UnL
』
. Than press
twice, controller will
restore factory setting.
Fahrenheit temperature/ degrees Celsius switching: press
and
for 3 seconds.
Manual system adjustment: press
for 3 seconds, LCD display”CCC”press twice
to enter manual adjustment. Now the LCD
codes display, all outputs stop, press
and
can turn R1-R7 in turns, SSR is on.
Warning control instruction
No.
Instruction
condition
delay
durati
on
reset
Action