background image

P Line Maritim HMI

Important Notes

7

1 Important Notes

1.1

Symbole

The symbols in this manual are used to draw your attention on notes and dangers.

1.2

Safety Notes

Read this manual carefully before using the operating device. Keep this man-
ual in a place where it is always accessible to all users.

Proper transportation, handling and storage, placement and installation of this 
product are prerequisites for its subsequent flawless and safe operation.

This user manual contains the most important information for the safe opera-
tion of the device.

The user manual, in particular the safety notes, must be observed by all per-
sonnel working with the device.

Observe the accident prevention rules and regulations that apply to the oper-
ating site.

Installation and operation must only be carried out by qualified and trained 
personnel.

This is the safety alert symbol. It is used to alert you to potential personal injury 
hazards. Obey all safety messages that follow this symbol to avoid possible in-
jury or death.

DANGER

This indicates a hazardous situation which, if not avoided, will result in death or 
serious injury.

WARNING

This indicates a hazardous situation which, if not avoided, could result in death 
or serious injury.

CAUTION

This indicates a hazardous situation which, if not avoided, could result in minor 
or moderate injury.

NOTICE

This symbol together with the signal word NOTE and the accompanying text 
alert the reader to a situation which may cause damage or malfunction to the 
device, hardware/software, or surrounding property.

This symbol and the accompanying text provide the reader with additional infor-
mation or refer to detailed sources of information.

Summary of Contents for TPEM070ZGW

Page 1: ...Date 2014 03 20 Valid for TPM070ZTW 10 80xxx100x xx TPM070ZGW 10 80xxx100x xx TPEM070ZGW 10 80xxx100x xx TPM121ZTM 10 80xxx100x xx TPM121ZGM 10 80xxx100x xx TPEM121ZGM 10 80xxx100x xx TPM150ZTX 10 80x...

Page 2: ...d party in departure from the copyright provision is forbidden No part of this manual may be reproduced trans lated or electronically or photographically archived or altered without the express writte...

Page 3: ...121ZTM TPM121ZGM TPEM121ZGM 17 2 2 2 4 TPM150ZTX TPM150ZGX TPEM150ZGX 18 2 2 3 Side View Mounting Depth 19 2 2 3 1 TPM070ZTW 19 2 2 3 2 TPM070ZGW TPEM070ZGW 20 2 2 3 3 TPM121ZTM TPM121ZGM TPEM121ZGM 2...

Page 4: ...Interfaces 42 4 4 1 CAN X12 X13 42 4 4 1 1 Pin Assignment 43 4 4 1 2 Cable 44 4 4 1 3 Termination 44 4 4 1 4 Diagnosis 45 4 5 Memory Card 46 4 5 1 Inserting the memory card 46 4 5 2 Ejecting the memo...

Page 5: ...M Line Maritim HMI Overall Table of Contents 5 6 10 TPEM150ZGX 71 7 Ordering Data 73 A Index 75...

Page 6: ...Overall Table of Contents M Line Maritim HMI 6...

Page 7: ...ting site Installation and operation must only be carried out by qualified and trained personnel This is the safety alert symbol It is used to alert you to potential personal injury hazards Obey all s...

Page 8: ...vior 1 4 Target Group The use of products described in this manual is oriented exclusively to Qualified electricians or persons instructed by them who are familiar with ap plicable standards and other...

Page 9: ...sioning 2 1 Unpacking the Device Unpack all parts carefully and check the contents for any visible damage in transit Also check whether the shipment matches the specifications on your delivery note If...

Page 10: ...Display 7 Display 7 Standard compass 0 75 m 29 527 2 2 m 86 614 Steering compass 0 45 m 17 716 1 35 m 53 149 NOTICE Damage When installing the device leave a gap of at least 30 mm 1 181 around the de...

Page 11: ...P Line Maritim HMI Installation and Commissioning 11 2 2 1 Front Panel Dimensions 2 2 1 1 TPM070ZTW Figure 2 2 TPM070ZTW...

Page 12: ...Installation and Commissioning P Line Maritim HMI 12 2 2 1 2 TPM070ZGW TPEM070ZGW Figure 2 3 TPM070ZGW TPEM070ZGW...

Page 13: ...P Line Maritim HMI Installation and Commissioning 13 2 2 1 3 TPM121ZTM TPM121ZGM TPEM121ZGM Figure 2 4 TPM121ZTM TPM121ZGM TPEM121ZGM...

Page 14: ...Installation and Commissioning P Line Maritim HMI 14 2 2 1 4 TPM150ZTX TPM150ZGX TPEM150ZGX Figure 2 5 TPM150ZTX TPM150ZGX TPEM150ZGX...

Page 15: ...P Line Maritim HMI Installation and Commissioning 15 2 2 2 Mounting Cutout 2 2 2 1 TPM070ZTW Figure 2 6 TPM070ZTW A Mounting Cutout B Front Panel...

Page 16: ...Installation and Commissioning P Line Maritim HMI 16 2 2 2 2 TPM070ZGW TPEM070ZGW Figure 2 7 TPM070ZGW TPEM070ZGW A Mounting Cutout B Front Panel...

Page 17: ...P Line Maritim HMI Installation and Commissioning 17 2 2 2 3 TPM121ZTM TPM121ZGM TPEM121ZGM Figure 2 8 TPM121ZTM TPM121ZGM TPEM121ZGM A Mounting Cutout B Front Panel...

Page 18: ...Installation and Commissioning P Line Maritim HMI 18 2 2 2 4 TPM150ZTX TPM150ZGX TPEM150ZGX Figure 2 9 TPM150ZTX TPM150ZGX TPEM150ZGX A Mounting Cutout B Front Panel...

Page 19: ...Installation and Commissioning 19 2 2 3 Side View Mounting Depth 2 2 3 1 TPM070ZTW Figure 2 10 TPM070ZTW 1 Mounting Bracket 2 Threaded Pin 3 Mounting Surface Thickness 1 mm to 6 mm 4 Circumferential...

Page 20: ...nd Commissioning P Line Maritim HMI 20 2 2 3 2 TPM070ZGW TPEM070ZGW Figure 2 11 TPM070ZGW TPEM070ZGW 1 Mounting Bracket 2 Threaded Pin 3 Mounting Surface Thickness 1 mm to 6 mm 4 Circumferential Seal...

Page 21: ...llation and Commissioning 21 2 2 3 3 TPM121ZTM TPM121ZGM TPEM121ZGM Figure 2 12 TPM121ZTM TPM121ZGM TPEM121ZGM 1 Mounting Bracket 2 Threaded Pin 3 Mounting Surface Thickness 1 mm to 6 mm 4 Circumferen...

Page 22: ...ioning P Line Maritim HMI 22 2 2 3 4 TPM150ZTX TPM150ZGX TPEM150ZGX Figure 2 13 TPM150ZTX TPM150ZGX TPEM150ZGX 1 Mounting Bracket 2 Threaded Pin 3 Mounting Surface Thickness 1 mm to 6 mm 4 Circumferen...

Page 23: ...ice has reverse polarity protection In case of wrong polarity the device will not operate This is a protection class I device For safe operation safety extra low voltage SELV in accordance with DIN EN...

Page 24: ...ding on the type of device with a slip on sleeve or a ring cable lug 3 Plug the slip on sleeve on the flat tab or mount the ring cable lug with the nut to the threaded bolt Figure 2 15 Noiseless groun...

Page 25: ...ss the button to start the cockpit before the progress bar is down You can customize the language of the cockpit interface at the language menu item 3 Press the button Language Selection 4 Select the...

Page 26: ...ce at the language menu item 1 Select the desired language 2 Confirm your selection with the green check Start Cockpit Normal Language Selection English German Date and Time Administration Information...

Page 27: ...rm your selection with the green check WINS DNS Optionally enter the addresses for the WINS DNS server Confirm your selection with the green check Device Name You can define a device name with a maxim...

Page 28: ...yed marks to calibrate the touch 2 4 1 2 7 Write Filter This category offers the following functions Enhanced write filter EWF File based write filter FBWF Hibernate once resume many HORM EWF The enha...

Page 29: ...n check 4 Restart the operating device for the changes to take effect HORM The current state of the system can be saved and restored automatically at every startup The boot process is accelerated by t...

Page 30: ...MI 30 2 5 Identification The operating device can be identified using the nameplate on the rear of the de vice Figure 2 17 Nameplate example 1 Device Type 2 Software Version Version on Delivery 3 MAC...

Page 31: ...h screen Exclusively therefore use the fingertips or the aids indicated in the technical data for the operation NOTICE Damage To protect the touch screen you can use special protection foils You recei...

Page 32: ...Control and Display Elements P Line Maritim HMI 32...

Page 33: ...of the Device 33 4 Interfaces of the Device Figure 4 1 Rear view 1 Slot for SD SDHC Memory Card 2 Ethernet X7 X6 10 100 1000 MBit 3 Female Connector X2 X5 USB Host Type A 4 Supply Voltage 5 Threaded...

Page 34: ...Line 1 Positive Polarity 2 D1 Data Line 1 Negative Polarity 3 D2 Data Line 2 Positive Polarity 4 D3 Data Line 3 Positive Polarity 5 D3 Data Line 3 Negative Polarity 6 D2 Data Line 2 Negative Polarity...

Page 35: ...ity 100 1000 MBit Green Flashing Sending Receiving activity 10 MBit 2 Yellow On 1000 MBit Green On 100 MBit Off 10 MBit NOTICE Using the USB interfaces while normal operating mode is not permitted for...

Page 36: ...t for SD SDHC Memory Card 2 Ethernet X7 X6 10 100 1000 MBit 3 Female Connector X2 X5 USB Host Type A 4 Supply Voltage 5 Diagnostics LEDs RS 422 RS 485 6 Termination Switch RS 422 RS 485 7 Male Connect...

Page 37: ...COM1 is assigned 4 3 1 1 Pin Assignment Figure 4 4 9 pin D SUB male connector strip Connector in the operating device 9 pin D SUB male connector strip Signal Logic 1 UA UB 0 3 V i e UA UB Signal Logi...

Page 38: ...at the two ends of the lines in a 2 or 4 wire multi point connection RS 422 RS 485 Figure 4 5 Termination possibilities RS 422 RS 485 intern Table 4 4 Resistance values termination RS 422 RS 485 Desig...

Page 39: ...ivated during the transmission On intermissions the trans mitter is highly resistive The receiver is disabled during the transmission The operating device does not receive the own transmit data at the...

Page 40: ...4 3 2 1 Pin Assignment Figure 4 6 9 pin D SUB male connector strip Connector in the operating device 9 pin D SUB male connector strip Table 4 7 Pin assignment RS 232 Pin Designation Function 1 nc Not...

Page 41: ...are located on the rear of the operating device The diagnostic LEDs at the operating device have the following functions Table 4 8 Functions of the RS 232 diagnostics LEDs Designation Color State Func...

Page 42: ...ype A 4 Supply Voltage 5 Male Connector X12 CAN1 6 Termination Switch CAN1 7 Diagnostics LEDs CAN1 8 Diagnostics LEDs Microcontroller 9 Male Connector X13 CAN2 10 Termination Switch CAN2 11 Diagnostic...

Page 43: ...CAN 1 Pin Designation Function 1 PE Shielding 2 Reserved Reserved for DeviceNet 3 CAN1_GND CAN Ground 4 CAN1_H CAN_H Bus Line 5 CAN1_L CAN_L Bus Line Table 4 10 Pin assignment CAN 2 Pin Designation Fu...

Page 44: ...ISO 11898 2 must be used A suitable cable with the designation SAC 5P 2 0 920 FS SCO is offerd by Phoenix Contact GmbH with article number 1518216 Table 4 11 Bit rate CAN Bit rate Cable length 125 kB...

Page 45: ...unctions Table 4 13 Functions of the CAN diagnostics LEDs Designation Color State Function CAN1 Green On Node is operational Green Flashes Node is not operational CAN2 Green Ein Node is operational Gr...

Page 46: ...rt the memory card until it clicks Figure 4 9 Inserting the memory card 4 5 2 Ejecting the memory card To remove push the memory card into the operating device until it clicks The memory card bounces...

Page 47: ...igure 4 10 Shielding D SUB connectors 1 D SUB connector 2 Shield 3 Cable clip 4 Cable The shield must be folded back into a flat position over the cable sheath When fastening the cable with the cable...

Page 48: ...Interfaces of the Device P Line Maritim HMI 48...

Page 49: ...nnected from the supply voltage to allow the semiconductor fuse to regenerate At an ambient temperature of 20 C 68 F the regeneration takes approximately 20 seconds The higher the ambient tem perature...

Page 50: ...vice 8 Carefully tighten the screws of the enclosure cover 9 Put the connector for the supply voltage on again 10 Set the current date and time Figure 5 1 Enclosure screws at the operating device NOTI...

Page 51: ...t the place of purchase According to the 11 of the battery law final consumers are obligedly to give old batteries back to gathering points which attached to the common take back sys tem or manufactur...

Page 52: ...Maintenance and Servicing P Line Maritim HMI 52...

Page 53: ...Mbit s Max 12 Mbit s Max output current 100 mA per output Central Processing Unit Central processing unit Intel Atom Clock frequency 1 6 GHz Memory RAM 2 GByte DDR2 Flash 8 GByte 16 GByte 32 GByte 64...

Page 54: ...ansporta tion EN 61131 part 2 Power supply EN 61131 part 2 Electromagnetic compati bility 2004 108 EG Degree of protection EN 60529 Impact load shocks EN 60068 part 2 27 Sinusoidal vibrations EN 60068...

Page 55: ...ors 262144 Reading angle vertical horizontal 130 140 Half life backlighting 40 000 h Brightness in cd m2 350 Display area H x W in mm Inch 91 4 x 152 4 3 598 x 6 0 Environmental Conditions Temperature...

Page 56: ...nclosure Steel sheet galvanized Front panel material Aluminium brushed black anodized Front panel H x W x D in mm Inch 147 x 203 x 5 5 787 x 7 992 x 0 197 Seal Circumferential rubber seal on the rear...

Page 57: ...eystroke element R8 silicon rubber Keystroke load 250 g Keystroke frequency 2 Hz Display Size diagonal in cm inch 17 78 7 Type TFT color Resolution pixels 800 x 480 Colors 262144 Reading angle vertica...

Page 58: ...against polarity reversal Integrated Front Panel and Enclosure Enclosure Steel sheet galvanized Front panel material Aluminium brushed black anodized Front panel H x W x D in mm Inch 148 x 208 x 5 5 8...

Page 59: ...ilicon rubber Keystroke load 250 g Keystroke frequency 2 Hz Display Size diagonal in cm inch 17 78 7 Type TFT color Resolution pixels 800 x 480 Colors 262144 Reading angle vertical horizontal 130 140...

Page 60: ...against polarity reversal Integrated Front Panel and Enclosure Enclosure Steel sheet galvanized Front panel material Aluminium brushed black anodized Front panel H x W x D in mm Inch 148 x 208 x 5 5 8...

Page 61: ...ors 262144 Reading angle vertical horizontal 176 176 Half life backlighting 50 000 h Brightness in cd m2 320 Display area H x W in mm Inch 163 2 x 261 12 6 425 x 10 28 Environmental Conditions Tempera...

Page 62: ...nclosure Steel sheet galvanized Front panel material Aluminium brushed black anodized Front panel H x W x D in mm Inch 225 x 330 x 5 8 858 x 12 992 x 0 197 Seal Circumferential rubber seal on the rear...

Page 63: ...roke element R8 silicon rubber Keystroke load 250 g Keystroke frequency 2 Hz Display Size diagonal in cm inch 30 73 12 1 Type TFT color Resolution pixels 1280 x 800 Colors 262144 Reading angle vertica...

Page 64: ...gainst polarity reversal Integrated Front Panel and Enclosure Enclosure Steel sheet galvanized Front panel material Aluminium brushed black anodized Front panel H x W x D in mm Inch 225 x 330 x 5 8 85...

Page 65: ...on rubber Keystroke load 250 g Keystroke frequency 2 Hz Display Size diagonal in cm inch 30 73 12 1 Type TFT color Resolution pixels 1280 x 800 Colors 262144 Reading angle vertical horizontal 176 176...

Page 66: ...gainst polarity reversal Integrated Front Panel and Enclosure Enclosure Steel sheet galvanized Front panel material Aluminium brushed black anodized Front panel H x W x D in mm Inch 225 x 330 x 5 8 85...

Page 67: ...ixels 1024 x 768 Colors 262144 Reading angle vertical horizontal 145 160 Half life backlighting 50 000 h Brightness in cd m2 480 Display area H x W in mm Inch 228 x 304 8 976 x 11 969 Environmental Co...

Page 68: ...losure Steel sheet galvanized Front panel material Aluminium brushed black anodized Front panel H x W x D in mm Inch 329 x 400 x 5 12 953 x 15 748 x 0 197 Seal Circumferential rubber seal on the rear...

Page 69: ...eystroke element R8 silicon rubber Keystroke load 250 g Keystroke frequency 2 Hz Display Size diagonal in cm inch 38 1 15 Type TFT color Resolution pixels 1024 x 768 Colors 262144 Reading angle vertic...

Page 70: ...ainst polarity reversal Integrated Front Panel and Enclosure Enclosure Steel sheet galvanized Front panel material Aluminium brushed black anodized Front panel H x W x D in mm Inch 329 x 400 x 5 12 95...

Page 71: ...ilicon rubber Keystroke load 250 g Keystroke frequency 2 Hz Display Size diagonal in cm inch 38 1 15 Type TFT color Resolution pixels 1024 x 768 Colors 262144 Reading angle vertical horizontal 145 160...

Page 72: ...ainst polarity reversal Integrated Front Panel and Enclosure Enclosure Steel sheet galvanized Front panel material Aluminium brushed black anodized Front panel H x W x D in mm Inch 329 x 400 x 5 12 95...

Page 73: ...scraper and instructions 81251 056 Protective foil for touch screen 7 Set with 10 protective foils scraper and instructions 81251 070 Protective foil for touch screen 9 Set with 10 protective foils sc...

Page 74: ...Ordering Data P Line Maritim HMI 74...

Page 75: ...30 Intended use 8 Interface CAN 42 RS 232 40 RS 422 37 RS 485 37 USB 35 M Maintenance 49 Maintenance interval 49 Memory card 46 Mounting 10 N Nameplate 30 Network 27 O Ordering data 73 P Password 27...

Page 76: ...76...

Page 77: ......

Page 78: ...S TRON electronic GmbH Kurze Stra e 29 D 70794 Filderstadt Phone 0049 711 77098 0 Fax 0049 711 77098 305 E Mail doku suetron de Internet www suetron com...

Reviews: