Sutron Corporation Satlink Operations & Maintenance Manual, Rev 8.04.2 11/3/2016 pg. 10
2.
General Safety Information
Read this manual before using Satlink for the first time. Become familiar with the
installation and operation of Satlink and its accessories.
Make sure that Satlink is protected against moisture (NEMA 4, IP 66 or better).
Operate Satlink only with approved antenna connected.
Protect the line of the battery supply voltage with a safety fuse (10A/fast).
Before connecting the power supply, check that all wires are properly attached to the
screw terminal strips.
Do not open Satlink. There are no user serviceable parts inside.
Have a defective Satlink checked and repaired by the Sutron repair center. Do not
attempt to repair Satlink yourself.
Operate Satlink only with approved antenna connected.
Symbol
Description
Direct current.
Protective earth ground. Connect to an earth ground electrode for lightening
protection of internal components.
Digital ground. Attach digital sensor ground to this terminal. Batteries and solar
panel negative terminals are also connected to this terminal.
Signal ground. Attach analog sensor ground to this terminal.
Chassis ground.
Shock hazard.
Do not dispose in trash.