TROUBLESHOOTING
MOTOR DOES NOT START
Tools is not plugged in: Check that all cords are
plugged in.
Fuse: Check the time-delayed fuse or circuit
breaker.
TOOL VIBRATES OR SHAKES
Damaged disc: Replace disc
Loose disc: Tighten arbor bolt.
If the machine presents other problems contact
your closest service center for maintenance.
TECHNICAL DATA
14
VOLTAGE-FREQUENCY
NO LOAD SPEED
DISC CAPACITY
POWER
WEIGHT
120 V ~ 60 Hz
8 100 r/min
7" (178 mm)
2 000 W
5,5 kg (12 lb)
VOLTAGE-FREQUENCY
NO LOAD SPEED
DISC CAPACITY
POWER
WEIGHT
120 V ~ 60 Hz
6 000 r/min
9" (229 mm)
2 000 W
5,5 kg (12 lb)
EA607
EA609
EA607 & EA609 manual.indd 14
26/06/15 9:26