Volcano Plus Revised August 2008
5
1-
SUPPORT INSTALLATION
Determine and cut supports to the proper size.
Note: The supports can overlap at the rear.
2-
CIRCULATING CHAMBER
INSTALLATION
The circulating chamber (patent pending:
GB1305647.8) is installed to maximize the air flow and increase the overall efficiency of the insert. The width of the
circulating chamber can be adjusted from 30 to 38 inches, the height at the front can be adjusted up to 28 inches and the
height at the rear end is 23 inches. The hole location for the liner connection can be adjusted as well up to 2 inches.
PIECES REQUIRED
1 Firebox
2 Fixing plate
3 Side support
4 Rear support
5 Flexible liner 6 in. dia. or a combination of
flexible and rigid liner 6 in. dia.
6 Flue collar
7 Flue collar flange
8 Face
VERIFICATION
Minimum size of the fireplace must be:
Depth 20 in.
Width 30 in.
Height 23 in.
FIGURE 2
Pieces required
3
8
6
4
7
1
5
COMBUSTION AIR
CONTROL HANDLE
20 5/16 ''
[516mm]
2
10 1/2 ''
[267mm]