12
3.4 Liner Adaptor Installation
Insert the 5” diameter liner adaptor (Section 2.12) at the end of the
liner. The liner must be flush with the inferior rim of the adaptor.
a) Tighten the clamp to secure the liner with the liner adaptor.
b) Secure the liner adaptor in place with the sheet metal screw
provided.
3.5 Firebox Installation
a) Slide the FUSION 18 firebox into the circulating chamber.
b) Align the liner adaptor with the flue of the insert.
c) Insert your hand in the chimney sweeping cap opening and
pull the liner down by its handle.
d) Use your thumb to bend the 4 tabs of the liner adaptor
outward to secure the liner in place.
e) Reposition the chimney sweeping cap back in the
chimney sweeping cap hole of the baffle (refer to Figure
17).
WARNING: The chimney sweeping cap should be blocking
the access to the chimney at all times during combustion.
A chimney sweeping cap that is not blocking the baffle
hole during combustion is a safety hazard, will overheat
the fireplace and void the warranty.
3.6 Power Cord Side Reversal
The blowers of the FUSION 18 insert are factory installed and
the power cord is located at the left side of the surround when
facing it (refer to Figure 18). However, the power cord location
can be switched to the right side by following the below
instructions:
a) Unfold the cover that secures the power cord in place.
b) Loosen the nut of the strain relief.
c) Bring the power cord to the opposite side and secure the
strain relief by tightening the nut.
d) Bend the cover to its original position.
Figure 17: Liner Adaptor Installation
Figure 19: FUSION 18 Installation
Figure 18: Location of Electric Wiring