background image

10 

 

3  INSTALLATION INSTRUCTIONS 

The  masonry  fireplace  is  to  be  constructed  in  accordance  to  N.F.P.A.  211  (Latest  Edition),  Standards  of 
Chimney,  Fireplaces,  Vents  and  Solid-Fuel-Burning  Appliances  and  Equipment.  The  FUSION  18  fireplace 
insert  is  intended  only  for  masonry  fireplaces  installed  with  a  continuous  chimney  liner  of  5  inch  diameter 
extending from the fireplace insert to the top of the chimney. This insert must be connected to a code-approved 
masonry chimney or listed factory-built fireplace chimney with a direct flue connector into the first chimney liner 
section. The chimney size should not be less than or more than three times greater than the cross-sectional 
area  of  the  flue  collar.  The  chimney  liner  must  conform  to  the  Class  3  requirements  of  CAN/ULC-S635, 
Standard  for  Lining  Systems  for  Existing  Masonry  or  Factory-Built  Chimneys  and  Vents  or  CAN/ULC-S640, 
Standard for Lining Systems for New Masonry Chimneys. Contact a local building inspector for information on 
additional requirements and/or codes in your area. 

CAUTION:  Read  these  instructions  carefully  before  starting  the  installation.  Failure  to  follow  these 
instructions  may  result  in  property  damage,  bodily  harm  and  even  death.  Modifications  of  the 
instructions presented in this section without written authorization from SUPREME FIREPLACES INC. 
will void the warranty. 

Be  sure  that  the  fireplace  and  chimney  are  clean  and  in  good 
condition. Seal all cracks using stove cement. Seal permanently 
any  openings  between  the  masonry  of  the  fireplace  and  the 
facing masonry. Remove or keep permanently open the existing 
damper of the fireplace. If there is an accumulation of creosote in 
the  chimney  or  flue,  it  must  be  thoroughly  cleaned.  When 
installing,  operating  and  maintaining  a  solid  fuel  heater,  respect 
basic standards for fire safety. 

WARNING: Do not remove bricks or mortar from the masonry fireplace. 

Refer to Table 1, Figure 13 and Figure 14 for minimum opening dimensions of the masonry fireplace. 

NOTE:

 The non-combustible hearth must extend a minimum of 20” (508mm) from the front and 8” (203mm) on 

each side of the masonry fireplace opening and must be a minimum of 44” long. 

      

Table 1: Minimum Opening Dimensions 

Width (Front) 

28’’ (711 mm) 

Width (Back) 

18’’ (457 mm) 

Height 

21.75’’ (553 mm) 

Depth 

19’’ (483 mm) 

Figure 13: Minimum Opening Dimensions – Front View 

Figure 14: Minimum Opening Dimensions – Side View 

Summary of Contents for FUSION 18

Page 1: ...Phase II particulate emission standards from the Environmental Protection Agency OWNER S MANUAL INSTALLATION OPERATION Important Keep the owner s manual for future use This product is proudly manufactured in North America by 3594 Jarry East Montreal QC H1Z 2G4 Tel 514 593 4722 Fax 514 593 4424 www supremem com Revised August 16th 2016 ...

Page 2: ...ble Legs 8 2 12 Liner Adaptor 8 2 13 Metal Tag 8 2 14 Serial Number 9 3 INSTALLATION INSTRUCTIONS 10 3 1 Preparing the Firebox for Installation 11 3 2 Liner Installation 11 3 3 Adjustable Circulating Chamber 11 3 3 1 Assembly 11 3 3 2 Installation 11 3 4 Liner Adaptor Installation 12 3 5 Firebox Installation 12 3 6 Power Cord Side Reversal 12 3 7 Surround Installation 13 3 8 Installation in a Fact...

Page 3: ...n 17 4 7 Barbecue Grill 18 5 TROUBLESHOOTING 19 5 1 Backdraft Smoking 19 5 2 Over Firing 19 6 MAINTENANCE 20 6 1 Disposal of Ashes 20 6 2 Chimney Maintenance 20 6 3 Cleaning of Glass 21 6 4 Replacement of Door Gasket 21 6 5 Replacement of Glass 21 6 6 Door Latch Lubrication 22 6 7 Paint 22 6 8 Removal of Firebox 22 6 9 Replacement Parts 23 7 WARRANTY 24 ...

Page 4: ...ing operation keep children pets flammable liquids or combustible materials at a safe distance Ensure that all clearances to combustible materials are respected Contact with the unit during operation may cause severe harm Install a safety screen to keep children and pets away CAUTION Do not connect this unit to a chimney flue serving another appliance Do not connect to any air distribution duct or...

Page 5: ...5 2 COMPONENTS 2 1 Overall Dimensions Figure 1 FUSION 18 Firebox Figure 2 Dimensions of FUSION 18 Firebox Figure 4 Dimensions of FUSION 18 with Circulating Chamber Figure 3 Dimensions of FUSION 18 ...

Page 6: ...omponents the Activator and the Burn Rate Selector The left combustion control lever is the Activator When starting a fire or adding a new load of wood the Activator must be pushed in to allow a primary source of air to enter the firebox The Activator will retract automatically with heat The right combustion control lever is the Burn Rate Selector The Burn Rate Selector can slide sideways to achie...

Page 7: ...with the FUSION 18 insert It is installed on the door holder under the two small angled tags below the door and prevents ashes from falling onto the front of the hearth The Ash Lip can be installed with the door open or closed It is safe to operate the unit without the Ash Lip 2 8 Blowers The FUSION 18 wood burning fireplace insert is equipped with two AC centrifugal compact fans on either side of...

Page 8: ... to rear NOTE The circulating chamber requires minimal adjustments Please refer to Section 3 4 for detailed instructions 2 11 Adjustable Legs The FUSION 18 insert is supplied with three adjustable legs see Figure 11 in the bottom of its firebox to allow adjustment of the height if the surround is not flushed with the wall of the masonry fireplace 2 12 Liner Adaptor The FUSION 18 Liner Adaptor is a...

Page 9: ...fied person prior to re use as a conventional fireplace Ce foyer a été modifié afin d y insérer un foyer encastrable et doit être inspecté par une personne qualifiée avant sa réutilisation comme foyer conventionnel 2 14 Serial Number The serial number of the unit is located at the bottom of the removable Ash Lip refer to Section 2 7 ...

Page 10: ...before starting the installation Failure to follow these instructions may result in property damage bodily harm and even death Modifications of the instructions presented in this section without written authorization from SUPREME FIREPLACES INC will void the warranty Be sure that the fireplace and chimney are clean and in good condition Seal all cracks using stove cement Seal permanently any openi...

Page 11: ...within the masonry fireplace Figure 16 ii Secure the bottom cover to the back wall of the circulating chamber and bend inwards the metal brackets at the front bottom CAUTION Ensure that the text on the Metal Tag Section 2 13 is facing upwards before installing the bottom cover 3 3 2 Installation i Measure the width of the existing fireplace ii Extend the width of the Circulating Chamber Section 2 ...

Page 12: ...he baffle refer to Figure 17 WARNING The chimney sweeping cap should be blocking the access to the chimney at all times during combustion A chimney sweeping cap that is not blocking the baffle hole during combustion is a safety hazard will overheat the fireplace and void the warranty 3 6 Power Cord Side Reversal The blowers of the FUSION 18 insert are factory installed and the power cord is locate...

Page 13: ... length stainless steel liner flexible or rigid that meets 2100 F or 1149 C HT requirements in UL 1777 or ULC S635 Canada The liner must be properly installed to the flue collar and the chimney top c Block any opening to the damper area to prevent room air entering the chimney cavity d The installation of the FUSION 18 must not block any existing air intake outtake louvers fresh air intakes and wa...

Page 14: ...rance of 36 75 from the bottom of the mantel to the base of the unit The depth of the mantle is measured from the face of the fireplace door When the non combustible wall is recessed the depth of the mantle can be increased by the amount of the recess Note that a mantel cannot be installed below the minimum clearance of 36 75 from the bottom of the mantel to the base of the unit Sidewall from oute...

Page 15: ...us and will void the warranty NOTE Gas logs cannot be installed in the FUSION 18 fireplace insert WARNING Never use gasoline gasoline type lantern fuel kerosene charcoal lighter fluid or similar liquids to start or freshen up a fire in this unit Keep all such liquids well away from the fireplace insert while it is in use Ecological or compressed logs containing chemical additives are not tested an...

Page 16: ... 4 4 Starting a Fire The FUSION 18 has patented technologies and innovative features that make starting a fire quick and easy Before starting a fire assure that all the safety precautions mentioned in the owner s manual are being respected The following instructions describe starting a fire in FUSION 18 fireplace using a top down approach which results in a cleaner more efficient and longer burn a...

Page 17: ...Completely latch the FUSION 18 door Assure that a flame is maintained Avoid wood smoldering on top of embers as this will result in a dirty glass excessive emissions chimney creosote buildup and poor heat output If wood is smoldering ensure the Activator has been activated and unlatch the door slightly with supervision until a flame has been maintained 4 6 Blower Operation A blower kit is preinsta...

Page 18: ...FUSION 18 insert comes with a removable swiveling barbecue grill When operating the FUSION 18 the barbecue grill should be leaning against the rear wall of the firebox in the upright position The grill swivels to the horizontal position above the bed of embers for cooking purposes The barbecue grill is removable by lifting the hinge and pulling forward Do not use the FUSION 18 insert as a primary ...

Page 19: ...ed by fans around the house such as in the kitchen and bathrooms simultaneously in operation insufficient length of the chimney less than 15 feet inadequate ventilation or a blocked chimney Refer to the following suggestions to eliminate backdraft Close any fans operating around the house specifically for the duration of ignition Clean the chimney of any obtrusions when the unit is cold Open one w...

Page 20: ...sidue accumulates on the flue lining When ignited this creosote makes an extremely hot fire The chimney connector and chimney burning wood or coal should be inspected at least once every two months during the heating season to determine if creosote buildup has occurred Note that continuously operating the unit with green or wet wood will result in premature creosote buildup Never use chemical clea...

Page 21: ...it for the FUSION 18 door gasket b Remove the door from the firebox and place it face down on a soft surface NOTE Rotate the handle to permit proper placing c Cover all painted surfaces of the door to avoid damages d Using a wedging tool or flat head screwdriver gently remove the old gasket along with the old silicone from the door framing e Apply a bead of high temperature silicone along the groo...

Page 22: ...ventilated area If applying paint to the door properly cover mask the glass of the door using painters tape and cardboard Wait for paint to dry before operating the unit Refer to the instructions on the label of the aerosol spray can for proper paint application WARNING Never apply paint to the unit during operation or when it is hot 6 8 Removal of Firebox Occasionally a technician or an inspector...

Page 23: ...hick 6 length GSK_25_6 Graphite coated square gasket 0 25 thick 6 length RG 125 19 06 AC centrifugal compact fan Electrical rating 115VAC 60Hz 19W Certification VDE CSA UL CE 60T22 Thermo disk Electrical rating 120VAC 15A Certification UL CSA B7059 Speed Control Electrical rating 300W 3 0 Amps 125VAC 50 60Hz Certification UL ULC PA5000 Combustion Air Control specify color CM0020 Cold Hand Key CPSP...

Page 24: ...s III From the sixth through the twenty fifth year of the limited lifetime warranty SUPREME FIREPLACES INC will provide replacement parts if available at 50 of the retail price except for the parts listed in the EXCLUSIONS portion of this warranty SUPREME FIREPLACES INC shall not be responsible for any labor costs Transportation packaging and other related costs or expenses arising from the replac...

Page 25: ...ll warranties currently in existence Please register your SUPREME product online at http www supremem com registration php to ensure full warranty coverage Prior to contacting SUPREME FIREPLACES INC have the following information available for warranty claim processing Customer information name telephone number and address Proof of purchase Model name and serial number see Section 2 7 Detailed des...

Reviews: