suprema BioEntry P2 Installation Manual Download Page 7

  Introduction 

Cables and connectors 

 

 

 

 

There are several conductors of size of AWG 26 and they shall be covered by a common jacket or the equivalent when field wiring; And the lead 
shall not be spliced to a conductor larger than 18 AWG (0.82 mm

2

). 

 

 

 

 

 

Note 

Pin 

Name 

Color 

RLY NO   

Gray (White stripe) 

RLY COM   

Green (White stripe)   

RLY NC   

Orange (White stripe) 

VB2 

Blue 

Brown 

VB1 

Red 

Green 

WG D0 

Green 

WG D1 

White 

WG GND 

Black 

TTL IN 1 

Brown 

10 

TTL IN 0 

Purple   

11 

PWR +VDC   

Red   

12 

Not Connected   

Pink   

13 

PWR GND   

Black (White stripe) 

14 

485 TRXN 

Yellow (Black stripe) 

15 

485 TRXP   

Blue (White stripe) 

16 

485 GND 

White (Black stripe) 

17 

ENET TXP   

White 

18 

ENET TXN 

Orange   

19 

ENET RXP 

Black 

20 

ENET RXN 

Yellow 

 

Summary of Contents for BioEntry P2

Page 1: ...English Version 1 24 BioEntry W2 INSTALLATION GUIDE www supremainc com EN 101 00 BEW2 V1 24A...

Page 2: ...P IP 11 TTL input connection 12 Relay connection 13 Fail Safe Lock 13 Fail Secure Lock 13 Automatic door connection 14 Connecting as a standalone 15 Connecting to Secure I O 2 16 Wiegand connection 17...

Page 3: ...t installation or repair of the product by the user free A S service will not be provided Operation Do not allowliquids suchas water beverages or chemicals get intothe product A fire electric shock or...

Page 4: ...es Deterioration in fingerprint authentication performance and a product failure may occur Whencleaningthe product wipe the product with a soft and dryclothand no water benzene or alcohol Otherwise a...

Page 5: ...Components Components may vary according to the installationenvironment Note BioEntry W2 Bracket PVC anchor 2 EA Fixing screw 2 EA Diode 1 EA 120 resistor 1 EA Drilling template Quick guide Ferrite c...

Page 6: ...ut cable Wiegand input or output cable Power cable RS485 cable Ethernet connector Relay output cable LEDlamp for Network Shows the status of the network connection Reset button Resets the network conf...

Page 7: ...te Pin Name Color 1 RLY NO Gray White stripe 2 RLY COM Green White stripe 3 RLY NC Orange White stripe 4 VB2 Blue Brown 5 VB1 Red Green 6 WG D0 Green 7 WG D1 White 8 WG GND Black 9 TTL IN 1 Brown 10 T...

Page 8: ...gain scan the fingerprint of a finger to be registered twice Cautions for enrolling afingerprint When a fingerprint is recognized it is compared with the initially registered fingerprint so the initia...

Page 9: ...sing fixing screws through the bracket to the position where BioEntryW2 will be installed If installing BioEntryW2 on a concrete wall drill holes insert PVC anchors and fixthem withfixing screws To av...

Page 10: ...Installation 10 2 Install BioEntryW2 onto the fixed bracket 3 Connect BioEntryW2 to the bracket by rotating the product fixing screw...

Page 11: ...ly adaptor you should use an adaptor with a current capacity which is the same or larger than the total power consumption required for the terminal and another device Use a separate power supply for S...

Page 12: ...utomatic MDI MDIX function so that it can be connected to a PC directly using a normal straight type CAT 5 cable not a cross cable TTL input connection BioEntry W2 9 TTL IN 1 Brown 10 TTL IN 0 Purple...

Page 13: ...or lock Fail Secure Lock In order to use the Fail Secure Lock connect N O relay as shown in the figure below There is normally no current flowing through the relay for the Fail Secure Lock When the cu...

Page 14: ...Installation 14 Automatic door connection BioEntry W2 Automatic door Controller Sensor Door Lock Door button 1 RLY NO Gray White stripe 2 RLY COM Green White stripe 2 1...

Page 15: ...of users and number of devices Also note that the number of slave devices affects the fingerprint authentication speed Amaster device can control 31slave devices The bandwidth of RS485 allows for upt...

Page 16: ...ices with the RS485 cable The slave devices are used as dummy readers and authentication is performed in the master device If Xpass is connected to the master device only card authenticationcan be use...

Page 17: ...RS 485 information 5 Turn the power off later on and then check the network setting is properly Restoring the Factory Defaults This will delete all data and root certificate on the device and reset th...

Page 18: ...00 dpi Template SUPREMA ISO 19794 2 ANSI 378 Extractor Matcher MINEX certified and compliant LFD Supported Capacity Max User 1 1 500 000 Max User 1 N 100 000 Max Template 1 1 1 000 000 Two templates p...

Page 19: ...Product specifications 19 Dimensions Unit mm 50 172 38 2 43 5 172 39 4 156 8...

Page 20: ...guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipm...

Page 21: ...uct names trademarks and registered trademarks are vested in each individual or organization that owns such rights Open Source License The software of this product is based on Linux Kernel 3 x which i...

Page 22: ...anizations To modify a work means to copy from or adapt all or part of the work in a fashion requiring copyright permission other than the making of an exact copy The resulting work is called a modifi...

Page 23: ...cation of the work as a means of enforcing against the work s users your or third parties legal rights to forbid circumvention of technological measures 4 ConveyingVerbatim Copies You may convey verba...

Page 24: ...vered work in that User Product from a modified version of its Corresponding Source The information must suffice to ensure that the continued functioning of the modified object code is in no case prev...

Page 25: ...eptance Not Required for HavingCopies You are not required to accept this License in order to receive or run a copy of the Program Ancillary propagation of a covered work occurring solely as a consequ...

Page 26: ...rder agreement or otherwise that contradict the conditions of this License they do not excuse you from the conditions of this License If you cannot convey a covered work so as to satisfy simultaneousl...

Page 27: ...xcluding any source code for portions of the CombinedWork that considered in isolation are based on the Application and not on the LinkedVersion The Corresponding Application Code for a CombinedWork m...

Page 28: ...ary as you received it specifies that a certain numbered version of the GNU Lesser General Public License or any later version applies to it you have the option of following the terms and conditions e...

Page 29: ...n binary form must reproduce the above copyright notice this list of conditions and the following disclaimer in the documentation and or other materials provided with the distribution 3 All advertisin...

Page 30: ...www supremainc com www supremainc com...

Reviews: