![suprema BioEntry P2 Installation Manual Download Page 15](http://html1.mh-extra.com/html/suprema/bioentry-p2/bioentry-p2_installation-manual_1406323015.webp)
Installation
15
Connecting as a standalone
BioEntry W2 can be connected to the door lock, door button, and door sensor directly without connecting a separate I/O device.
•
BioEntry W2 can be used as a multi-door controller with the slave devices with the RS485 cable. The slave devices are used as dummy readers and
authentication is performed in the master device.
•
If Xpass is connected to the master device, only card authentication can be used.
•
The maximum number of slave devices available to connect varies according to the authentication method, number of users, and number of
devices. Also note that the number of slave devices affects the fingerprint authentication speed.
•
A master device can control 31 slave devices. The bandwidth of RS485 allows for up to 7 fingerprint authentication devices to be connected.
•
For more information, contact the Suprema technical support team ([email protected]).
Note
BioEntry W2
PC
Relay
Door sensor
Door button
1
2
3
11
13
DC
power
DC
power
Deadbolt /
Door strike
Hub
Fail Safe Lock
Fail Secure Lock
or
Power
16
9
16
10
TTL connection
9 - TTL IN 1
Brown
10 - TTL IN 0
Purple
16 - 485 GND
White (Black stripe)
Relay connection
1 - RLY NO
Gray (White stripe)
2 - RLY COM
Green (White stripe)
3 - RLY NC
Orange (White stripe)
Power supply connection
11 - PWR +VDC
Red
13 - PWR GND
Black (White stripe)