3.1How to determine whether the flowmeter is working properly

Under normal circumstances, in the lower right corner of the LCD display with "R"
appears, that the flowmeter is working properly. If "H" appears, it means that the
received signal is poor, please refer to the self-diagnosis chapter.
If "I" appears, it means that no signal is received.
If "J" appears, it means the flowmeter may have a hardware failure, please refer to
the self-diagnosis chapter.

3.2 How to determine the direction of liquid flow in the pipeline

Make sure the current flowmeter is working properly.
Check the instantaneous flow, if the display is a positive value, the direction of
liquid flow from the red sensor to the blue sensor: if the display is a negative value,
the direction of liquid flow from the blue sensor to the red sensor.

3.3 How to change the measurement unit system

Select the imperial or metric system in the M30 menu window.

3.4 How to select the flow unit

Select in the menu window M31.
After selecting the flow rate unit, select the time unit.

3.5 How to select the accumulator multiplier

Use window M33 to select an appropriate accumulator multiplier, not too fast or too
slow, depending on the flow rate, and preferably keep it to a few pulses per minute.
If the multiplication factor is too small, lost pulses will occur, as the minimum pulse
period is designed to be 500 milliseconds.
If the multiplication factor is too large, the accumulated pulses will be too slow,
which will affect the work of other secondary instruments.

3.6 How to open and close the accumulator

Use M34,M35 and M36 to turn the positive, negative and net accumulators on and
off respectively.

Summary of Contents for SUP-2100H Series

Page 1: ...a Automation Co Ltd www supmea com Headquarters 5th floor Building 4 Singapore Hangzhou Science Technology Park No 6 street Hangzhou Economic Development Area Hangzhou 310018 China Singapore 2 Venture...

Page 2: ...o incorrect operation After you finish reading please keep it in a place where it can be easily accessed at any time for reference during operation Note Modification of this manual s contents will not...

Page 3: ...mistakes If the instrument is operated in other ways not described in the manual the protections that the instrument give may be destroyed and the failures and accidents incurred due to violation of...

Page 4: ...level shielded wires shall be located rationally SPD surge protector shall be applied properly Some inner parts may carry high voltage Do not open the square panel in the front except our company per...

Page 5: ...fines or other objects from entering the instrument during installation otherwise it will cause abnormal movement or failure During operation to modify configuration signal output startup stop operati...

Page 6: ...r unpredictable damage caused directly or indirectly by improper operation of the user Package contents After opening the box please confirm the package contents before starting the operation If you f...

Page 7: ...rangement 12 2 6 Steps to Configure the Parameters 12 2 7 Transducers Mounting Allocation 14 2 8 Transducers lnstallation 16 2 8 1 Transducers spacing 16 2 8 2 V method Installation 17 2 8 3 Z method...

Page 8: ...logger 22 3 15 How to use the frequency output function 22 3 16 How to set the cumulative pulse output 23 3 17 How to generate the output alarm signal I 23 3 18 How to use the buzzer 24 3 19 How to us...

Page 9: ...Chapter 6 Communication Protocol 36 6 1 General 36 6 2 Interface Pin out Definition 36 6 3 The Protocol 37 6 3 Protocol Prefix Usage 38 6 4 Codes for the Keypad 39 Chapter 7 Warranty After sales Servi...

Page 10: ...ed from the famous semiconductor manufacturers like Philips Maxim TI win bond and xilinx The hardware features the ease of operation high accuracy and outstanding reliability while the software provid...

Page 11: ...00H transit time flow meter utilizes two transducers that function as both ultrasonic transmitters and receivers The transducers are clamped on the outside of a closed pipe at a specific distance from...

Page 12: ...direction M is the travel times of the ultrasonic beam D is the pipe diameter Tup is the time for the beam from upstream transducer to the downstream one Tdown is the time for the beam from downstream...

Page 13: ...Chapter 1 Introduction www supmea com 4...

Page 14: ...Chapter 1 Introduction www supmea com 5...

Page 15: ...5 Typical Applications The SUP 2100H flow meter can be virtually applied to a wide range of measurements The measured pipe ranges 20 6000 mm 0 5 200 inch A variety of liquid applications can be accom...

Page 16: ...ase of flow accumulation It keeps operating as long as the battery s terminal voltage is over 1 5V In case of battery failure the time keeper will not keep running and it will lose proper time values...

Page 17: ...Manual Totalizer 7 digit press key to go totalizer for calibration Housing Material ABS Case Size 100x66x20mm Handset weight 514g 1 2 lbs with batteries Chapter 2 Starting Measurement 2 1 Built in Bat...

Page 18: ...software integrity If there is any abnormality corresponding error messages will display Generally there should be no display of error messages and the flow meter will go to the most commonly used Me...

Page 19: ...en entering numbers Key is backspace key when the user wants go left or wants backspace the left character that is located to the left of the cursor Key is the ENTER key for any inputting or selection...

Page 20: ...or the option selection windows the user should first press the ENT key to enter into a selection modification mode then either make the selection by pressing the and keys to select the option with a...

Page 21: ...ter setups M 0 M 8 are windows for some additional functions including a scientific calculator viewer on records such as total working hours turn on and turn off times dates and times when the flow me...

Page 22: ...M11 window to input the digits for the pipe outer diameter and then press key 2 Press key to enter M12 window to input the digits for the pipe outer diameter and then press key 3 Press key to enter M...

Page 23: ...to M09 press a number key x the user will go directly to the M0x window For example if the current window displays M0l press 7 and the user will go to M07 2 when the window display is under M00 to M0...

Page 24: ...d make sure that the pipe is completely full of liquid 2 Make sure that the temperature on the location does not exceed the range for the transducers Generally speaking the closer to the room temperat...

Page 25: ...ucers are critical factors to the accuracy of the measurement and the performance of the system Meticulous care should be taken for the installation of the transducers steps to the installation of the...

Page 26: ...e inner diameters ranging from 20 millimeter to 300 millimeter It is also called reflective mode or method 2 8 3 Z method Installation Z method is commonly used when the pipe diameter is between 300 m...

Page 27: ...nal detected and 999 refers to the maximum signal strength that can be received Although the instrument works well if the signal strength ranges from 500 to 999 stronger signal strength should be purs...

Page 28: ...ime respectively They are the primitive data for the instrument to calculate the flow rate inside the pipe so the flow rate indication will vary accordingly with the total time and delta time The tota...

Page 29: ...nsor if the display is a negative value the direction of liquid flow from the blue sensor to the red sensor 3 3 How to change the measurement unit system Select the imperial or metric system in the M3...

Page 30: ...lue The flowmeter treats flow rates below this value as 0 in absolute terms This parameter can be set to avoid a false accumulation of measurement errors generated by the meter when the true flow rate...

Page 31: ...dow M52 to select the data storage direction the meter can store the data in a buffer Data can also be transferred to the RS 232C interface without being stored in a buffer Use window M53 to view the...

Page 32: ...tor x 0 1 In window M77 select Positive cumulative pulse output 3 17 How to generate the output alarm signal I Ultrasonic flowmeter can generate two types of alarm signals audible alarm signal and swi...

Page 33: ...ely depleted and it takes a long time to replace the battery is it necessary to change the date To change the date and time in the M61 window you can use the A key to skip the part that does not need...

Page 34: ...ntifier containing software version and production date information Users can also use this electronic serial number for device management This electronic serial number is displayed in the M61 window...

Page 35: ...e and time flow rate signal strength signal quality and working status M05 Display date and time velocity signal strength signal quality and working status M06 Display the wave shape of the receiving...

Page 36: ...ryol 6 Polystyrene 7 Polyester 8 Polyethylene 9 Ebonite l0 Teflon M17 Window for entering the liner material speed only for non standard liner materials M18 Window for entering the liner thickness if...

Page 37: ...ntry to load one set of saved parameters M28 Select YES or NO for the instrument to determine whether or not to hold or to keep the last correct value when poor signal condition occurs YES is the defa...

Page 38: ...ible that more than 2 billions of people on the world can read the menu M40 Flow rate damper for a stable value The input range is 0 to 999 seconds 0 means there is no damping Default value is 10 seco...

Page 39: ...ger memory 3 Buffer transferring and buffer clearing M53 Logger buffer viewer It functions as a file editor Use Dot backspace UP and DN keys to browse the buffer If the logger is ON the viewer will au...

Page 40: ...Flow Rate value that will trigger the 1 Alarm Thereare two virtual alarms in the system By virtual we mean that the user must redirect the output of the alarms by setting up the output hardware in M7...

Page 41: ...d pipe parameters entered and the transducer installation should be checked again M93 Displays total transit time and delta time transit time difference M94 Displays the Reynolds number and the pipe f...

Page 42: ...ovides an automatic power on diagnosis for the hardware problems when any message with the power on in the following table displays counter measures should be taken Error message Causes Counter measur...

Page 43: ...ter measures R System Normal No error I Detect No signal 1 No signals detected 2 Transducers installed improperly 3 Too much fouling 4 Pipe liners are too thick 5 Transducer cords are not properly con...

Page 44: ...in for the signal and the number indicates the progressive steps K Empty pipe 1 No liquid inside pipe 2 setup error on M29 1 Relocate where the pipe is full of liquid 2 Enter 0 on M29 5 3 Other Proble...

Page 45: ...en Please contact the factory c The battery has not been fully recharged or the recharge has been stopped too many times halfway d There is indeed a time difference between the actual working time and...

Page 46: ...dE dd CR LF DV CR Return flow velocity d ddddddE dd CR LF DI CR Return POS totalizer dddddddE d CR LF DI CR Return NEG totalizer dddddddE d CR LF DIN CR Return NET totalizer dddddddE d CR LF DID CR Re...

Page 47: ...cation Number in a network environment The IDN is a word ranging 0 65534 N Prefix before an Identification Number in a network environment The IDN is a single byte value ranging 00 255 P Prefix before...

Page 48: ...en 0 and 65534 except 13 0DH 10 0AH 42 2AH 38 26H For example if the IDN 12345 instrument is addressed and returning the velocity of that instrument is requested the command will be w12345DV CR 3 Pref...

Page 49: ...h the keypad code By this function remote operation of this instrument can be realized even via the Internet Key Hexadecima1 Key code Decimal Key code ASCII Code 0 30H 48 0 1 31H 49 1 2 32H 50 2 3 33H...

Page 50: ...e and all non customized products are guaranteed to be returned and replaced within 7 days Disclaimers During the warranty period product faults caused by the following reasons are not in the scope of...

Reviews: