Chapter 2: Installation
2-17
Power Button
Blue+ (OH/Fan Fail/
PWR FaiL/UID LED)
1
NIC1 Link LED
Reset Button
2
Power Fail LED
HDD LED
FP PWRLED
Reset
PWR
3.3 V
ID_UID_SW/3/3V Stby
Red+ (Blue LED Cathode)
Ground
Ground
19
20
3.3V
X
Ground
NMI
X
NIC2 Link LED
NIC2 Activity LED
NIC1 Activity LED
Unit Identifier Switch
A Unit Identifier (UID) Switch and two
LED Indicators are located on the
motherboard. The UID Switch is lo-
cated next to the VGA port. The Rear
UID LED (LED3) is located next to
the UID Switch. The Front Panel UID
LED is located at Pins 7/8 of the Front
Control Panel at JF1. Connect a cable
to Pin 8 on JF1 for Front Panel UID
LED indication. When you press the
UID switch, both Rear UID LED and
Front Panel UID LED Indicators will
be turned on. Press the UID switch
again to turn off both LED Indicators.
These UID Indicators provide easy
identification of a system unit that
may be in need of service.
Note:
UID can also be trig-
gered via IPMI on the moth-
erboard. For more informa-
tion on IPMI, please refer
to the IPMI User's Guide
posted on our Website @
http://www.supermicro.com.
UID Switch
Pin# Definition
1
Ground
2
Ground
3
Button In
4
Ground
1. UID Switch
2. Rear UID LED (LED3)
3. Front UID LED
UID LED
Status
Color/State OS Status
Blue: On
Windows OS
Unit Identified
Blue:
Blinking
Linux OS
Unit Identified
3
X9DRW-3F/iF
Rev. 1.02
1
2 3
Summary of Contents for X9DRW-3F
Page 1: ...USER S MANUAL Revision 1 0 X9DRW 3F X9DRW iF...
Page 24: ...1 16 X9DRW 3F X9DRW iF Motherboard User s Manual Notes...
Page 62: ...2 38 X9DRW 3F X9DRW iF Motherboard User s Manual Notes...
Page 102: ...A 2 X9DRW 3F X9DRW iF Motherboard User s Manual Notes...
Page 106: ...B 4 X9DRW 3F X9DRW iF Motherboard User s Manual Notes...