1-4
SUPERSERVER 6027TR-H71QRF/H71FRF/H71RF USER'S MANUAL
1-3 Server Chassis Features
The following is a general outline of the main features of the SC827 server chassis.
System Power
Each SC827 chassis model includes a high-effi ciency 80-plus Platinum certifi ed
power supply, rated at 1620 Watts plus one redundant backup power supply.
In the unlikely event your power supply fails, replacement is simple and can be
accomplished without tools.
SAS/SATA Subsystem
The SC827 supports up to twelve (12) 3.5" hot-swap SAS/SATA drives in trays
(3 for each node). These drives are hot-swappable units and are connected to a
backplane that provides power and control.
Note:
The operating system you use must have RAID support to enable the hot-
swap capability of the drives.
Front Control Panel
SC827HQ-R1620B chassis includes four front panels on the handles of the chassis
which control each of the systems. Each control panel on the SUPERSERVER
6027TR-H71QRF/H71FRF/H71RF provides you with system monitoring and control
for one server node. LEDs indicate system power, HDD activity, network activity,
system overheat and power supply failure. A main power button and a system reset
button are also included.
I/O Ports
The SC827 is an proprietary form factor chassis designed to be used in a 2U
rackmount confi guration. The SC827 chassis provides a low-profi le add-on card
slot, a COM port, a VGA port, two USB 2.0 ports , one IPMI Ethernet port and two
gigabit Ethernet ports per node.
Cooling System
The SC827 chassis accepts four system fans powered from either backpane
or the serverboards. If not powered from the backpane, the SC827HQ-R1620B
model chassis powers four fans from four motherboards, so that when one of the
motherboard drawers is removed, the other motherboards will continue running
all fans.
Summary of Contents for SUPERSERVER 6027TR-H71FRF
Page 1: ... SUPER USER S MANUAL Revision 1 0 SUPERSERVER 6027TR H71QRF 6027TR H71FRF 6027TR H71RF ...
Page 5: ...v SUPERSERVER 6027TR H71QRF H71FRF H71RF USER S MANUAL Notes ...
Page 10: ...x Notes SUPERSERVER 6027TR H71QRF H71FRF H71RF USER S MANUAL ...
Page 28: ...2 10 SUPERSERVER 6027TR H71QRF H71FRF H71RF USER S MANUAL Notes ...
Page 32: ...SUPERSERVER 6027TR H71QRF H71FRF H71RF USER S MANUAL 3 4 Notes ...
Page 66: ...5 6 SUPERSERVER 6027TR H71QRF H71FRF H71RF USER S MANUAL Notes ...
Page 73: ...Chapter 6 Advanced Chassis Setup 6 7 Figure 6 5 Replacing a System Fan in the Fan Housing ...
Page 114: ...A 2 SUPERSERVER 6027TR H71QRF H71FRF H71RF USER S MANUAL Notes ...