Choosing a Setup Location
- Leave enough clearance in front of the rack to enable you to open the front
door
completely
(~25
inches).
- Leave approximately 30 inches of clearance in the back of the rack to allow
for suffi cient airfl ow and ease in servicing.
-This product is for installation only in a Restricted Access Location (dedicated
equipment rooms, service closets and the like).
- This product is not suitable for use with visual display work place devices ac-
cording to §2 of the the German Ordinance for Work with Visual Display Units.
Rack Precautions
- Ensure that the leveling jacks on the bottom of the rack are fully extended to the
fl oor with the full weight of the rack resting on them.
- In single rack installation, stabilizers should be attached to the rack.
- In multiple rack installations, the racks should be coupled together.
- Always make sure the rack is stable before extending a component from the
rack.
- You should extend only one component at a time - extending two or more simul-
taneously may cause the rack to become unstable.
Server Precautions
- Review the electrical and general safety precautions in Chapter 4.
- Determine the placement of each component in the rack
before
you install the
rails.
-
Install the heaviest server components on the bottom of the rack fi rst, and then
work up.
- Use a regulating uninterruptible power supply (UPS) to protect the server from
power surges, voltage spikes and to keep your system operating in case of a power
failure.
-
Allow the hot plug SATA/SCSI drives and power supply units to cool before touch-
ing
them.
-
Always keep the rack's front door and all panels and components on the servers
closed when not servicing to maintain proper cooling.
!
!
Warnings and Precautions!
Summary of Contents for SUPERSERVER 6025B-8R+
Page 1: ...SUPERSERVER 6025B TR SUPERSERVER 6025B 8R SUPER USER S MANUAL 1 0b...
Page 5: ...v Preface Notes...
Page 10: ...Notes x SUPERSERVER 6025B TR 6025B 8R User s Manual...
Page 21: ...Chapter 2 Server Installation 2 5 Figure 2 1 Installing Chassis Rails...
Page 23: ...Chapter 2 Server Installation 2 7 Figure 2 2 Installing the Server into a Rack...
Page 25: ...Chapter 2 Server Installation 2 9 Figure 2 3 Accessing the Inside of the System...
Page 30: ...SUPERSERVER 6025B TR 6025B 8R User s Manual 3 4 Notes...
Page 96: ...A 6 SUPERSERVER 6025B TR 6025B 8R User s Manual Notes...
Page 102: ...B 6 SUPERSERVER 6025B TR 6025B 8R User s Manual Notes...
Page 116: ...C 14 SUPERSERVER 6025B TR 6025B 8R User s Manual Notes...
Page 120: ...D 4 SUPERSERVER 6025B TR 6025B 8R User s Manual Notes...