Chapter 7: BIOS
7-15
X
Console Redirection
Access the submenu to make changes to the following settings.
COM Port Address
This item allows you to specify which COM port to direct the remote console to:
Onboard COM A or Onboard COM B. This setting can also be
Disabled
.
BAUD Rate
This item allows you to set the BAUD rate for the console redirection. The options
are 300, 1200, 2400, 9600,
19.2K
, 38.4K, 57.6K, and 115.2K.
Console Type
This item allows you to choose the console redirection type. The options are VT100,
VT100/8bit, PC-ANSI/7bit,
PC ANSI
, VT100+, and VT-UTF8.
Flow Control
This item allows you to set the fl ow control for the console redirection. The options
are: None, XON/XOFF, and
CTS/RTS
.
Console Connection
This item allows you to decide how the console redirection is to be connected:
either
Direct
or Via Modem.
Continue CR after POST
This item allows you to decide whether you want to continue with the console
redirection after POST routines. The options are On and
Off
.