![Supero SUPERSERVER 6015C-M3 User Manual Download Page 102](http://html1.mh-extra.com/html/supero/superserver-6015c-m3/superserver-6015c-m3_user-manual_1405677102.webp)
C-2
S
UPER
S
ERVER 6015C-M3/6015C-MT User's Manual
The Intel HostRAID Confi gurations
The following types of Intel's HostRAID confi gurations are supported:
RAID 0 (Data Striping): this writes data in parallel, interleaved ("striped") sections
of two hard drives. Data transfer rate is doubled over using a single disk.
RAID1 (Data Mirroring): an identical data image from one drive is copied to another
drive. The second drive must be the same size or larger than the fi rst drive.
RAID 10 (Striping & Mirroring): RAID 0 and 1 schemes are combined (without
parity information) to get the benefi ts of both.
RAID 5: both data and parity information are striped and mirrored across three
or more hard drives.
The Intel Matrix Storage
The Intel Matrix Storage, supported by the ICH9R, allows the user to create RAID
0, RAID 1, RAID 10 and RAID 5 by using only six identical hard disk drives. The
Intel Matrix Storage Technology creates two partitions on each hard disk drive,
and generate a virtual RAID 0, RAID 1, RAID 10 and RAID 5 sets. It also allows
you the change the HDD partition size without losing any data.
Confi guring BIOS settings for SATA RAID Functions (Native Mode)
1. Press the <Del> key during system bootup to enter the BIOS Setup Utility.
Note
: If it is the fi rst time powering on the system, we recommend that you load the
Optimized Default Settings. If you have already done so, please skip to Step 3.
2. Use the arrow keys to select the "Exit" Settings in the BIOS. Once in the "Exit"
settings, Scroll down to select "Load Optimized Default Settings" and press the
<Enter> key. Select "OK" to confi rm the selection. Press the <Enter> key to load
the default settings for the BIOS.
3. Use the arrow keys to select the "Main" menu in BIOS.
4. Scroll down to "SATA Controller Mode" and press the <Enter> key to select
"Enhanced"
5. Scroll down to "SATA RAID Enabled" and press <Enter>. Then, select "En-
abled."
6. Scroll down to "Exit". Select "Save and Exit" from the "Exit" menu. Press the
<Enter> key to save the changes and exit the BIOS.
7. Once you've exited the BIOS Utility, the system will re-boot.
8. During the system bootup, press the <Ctrl> and <I> keys simultaneously to
run the Intel RAID Confi guration Utility when prompted by the following message:
Press <Ctrl> <I> for the Intel RAID Confi guration Utility.
Note: T
he Intel RAID Confi guration Utility is only available for systems with two
or more drives installed. The Intel RAID Utility screen will not display in systems
with one drive installed.
Summary of Contents for SUPERSERVER 6015C-M3
Page 1: ...SUPER USER S MANUAL Revision 1 0a SUPERSERVER 6015C M3 SUPERSERVER 6015C MT...
Page 5: ...v Preface Notes...
Page 10: ...SUPERSERVER 6015C M3 6015C MT User s Manual x...
Page 30: ...3 4 SUPERSERVER 6015C M3 6015C MT User s Manual Notes...
Page 58: ...5 24 SUPERSERVER 6015C M3 6015C MT User s Manual Notes...
Page 94: ...A 6 SUPERSERVER 6015C M3 6015C MT User s Manual Notes...
Page 100: ...B 6 SUPERSERVER 6015C M3 6015C MT User s Manual Notes...
Page 114: ...D 4 SUPERSERVER 6015C M3 6015C MT User s Manual Notes...