3-2
S
UPER
S
ERVER 1026GT-TF Series User's Manual
2
1
NIC2
Indicates network activity on GLAN2 when fl ashing .
3-3 Control Panel LEDs
The control panel located on the front of the SC118G chassis has fi ve LEDs. These
LEDs provide you with critical information related to different parts of the system.
This section explains what each LED indicates when illuminated and any corrective
action you may need to take.
NIC1
Indicates network activity on GLAN1 when fl ashing .
Overheat/Fan Fail
When this LED fl ashes it indicates a fan failure. When continuously on (not fl ashing)
it indicates an overheat condition, which may be caused by cables obstructing the
airfl ow in the system or the ambient room temperature being too warm. Check the
routing of the cables and make sure all fans are present and operating normally.
You should also check to make sure that the chassis covers are installed. Finally,
verify that the heatsinks are installed properly. This LED will remain fl ashing or on
as long as the overheat condition exists.