Chapter 2: Installation
2-15
CMOS Clear
Refer to Table 2-25 for instructions
on how to clear CMOS. Always re-
move the AC power cord from the
system before clearing CMOS.
Note: For an ATX power supply,
you must completely shut down
the system, remove the AC power
cord, and then use JBT1 to clear
CMOS. Replace JBT1 back to the
pin 1-2 position before powering
up the system again. Do not use
the PW_ON connector to clear
CMOS.
Position
1-2
Position
2-3
Normal
CMOS Clear
T a b le 2 -2 5
C M O S C le a r J u m p e r S e ttin g s
(J B T 1 )
Ju m p e r
P o sitio n
1 -2
2 -3
D e fin itio n
N o rm a l
C M O S C le a r
PCI 64 Speed Select
(P4DC6+ only)
Jumper JPA3 allows you to change
the speed of the 64-bit PCI slot.
The default setting is 66 MHz.
Note: If you have installed a RAID
card into the RAID adapter port and
a PCI slot into the 64-bit 66 MHz
PCI slot, you must set this jumper
to 33 MHz. Refer to Table 2-26 for
jumper settings.
Ju m p e r
P o sitio n
O p e n
C lo se d
D e fin itio n
6 6 M H z
3 3 M H z
T a b le 2 -2 6
6 4 -b it P C I S p ee d S e le c t
J u m p e r S e tting s (J P A 3 )
Summary of Contents for SUPER P4DC6
Page 1: ...SUPER P4DC6 SUPER P4DC6 USER S MANUAL Revision 1 1 SUPER...
Page 9: ...Chapter 1 Introduction 1 3 Notes...
Page 10: ...SUPER P4DC6 P4DC6 User s Manual 1 4 SUPER P4DC6 Figure 1 1 SUPER P4DC6 Image...
Page 11: ...Chapter 1 Introduction 1 5 SUPER P4DC6 Figure 1 2 SUPER P4DC6 Image...
Page 26: ...SUPER P4DC6 P4DC6 User s Manual 1 20 Notes...
Page 48: ...2 22 SUPER P4DC6 P4DC6 User s Manual Notes...
Page 80: ...SUPER P4DC6 P4DC6 User s Manual 4 26 Notes...