H8DCL-i/6(F) Serverboard User's Manual
2-10
NIC2 (LAN2) LED
The LED connections for LAN2 are on pins
9 and 10 of JF1. Attach LAN LED cables to
display network activity. See the table on the
right for pin defi nitions.
HDD LED
The HDD LED connection is located on pins
13 and 14 of JF1. Attach the hard drive LED
cable here to display disk activity (for any
hard drives on the system, including SAS,
Serial ATA and IDE). See the table on the
right for pin defi nitions
NIC1 LED
Pin Defi nitions
(JF1)
Pin# Defi nition
11
Vcc
12
Ground
NIC2 LED
Pin Defi nitions
(JF1)
Pin# Defi nition
9
Vcc
10
Ground
NIC1 (LAN1) LED
The LED connections for LAN1 are on pins
11 and 12 of JF1. Attach LAN LED cables to
display network activity. See the table on the
right for pin defi nitions.
HDD LED
Pin Defi nitions
(JF1)
Pin# Defi nition
13
Vcc
14
HD Active
Reset Connector
The reset connector is located on pins 3 and
4 of JF1 and attaches to the reset switch on
the computer chassis. See the table on the
right for pin defi nitions.
PW_ON Connector
The PW_ON connector is on pins 1 and 2 of
JF1. This header should be connected to the
chassis power button. See the table on the
right for pin defi nitions.
Overheat/Fan Fail LED (OH)
Connect an LED to the OH connection on
pins 7 and 8 of JF1 to provide advanced
warning of chassis overheating or fan
failure. Refer to the table on the right for pin
defi nitions and status indicators.
Reset Button
Pin Defi nitions
(JF1)
Pin# Defi nition
3
Reset
4
Ground
Power Button
Pin Defi nitions
(JF1)
Pin# Defi nition
1
PW_ON
2
Ground
OH/Fan Fail LED
Pin Defi nitions
(JF1)
Pin# Defi nition
7
Vcc
8
Control
OH/Fan Fail
LED Status
State Indication
Solid
Overheat
Blinking
Fan fail