A+ SERVER 4042G-6RF/TRF User's Manual
Installing the Rack Rails
Determine where you want to place the 4042G-6RF/TRF in the rack. (See Rack
and Server Precautions in Section 2-3.) Position the fixed rack rail/sliding rail guide
assemblies at the desired location in the rack, keeping the sliding rail guide facing
the inside of the rack. Screw the assembly securely to the rack using the brackets
provided. Attach the other assembly to the other side of the rack, making sure both
are at the exact same height and with the rail guides facing inward.
Stability hazard
. The rack stabilizing mechanism must be in place, or the
rack must be bolted to the floor before you slide the unit out for servicing.
Failure to stabilize the rack can cause the rack to tip over.
Warning:
Do not pick up the server with the front handles. They are designed
to pull the system from a rack only.
Figure 2-3. Installing the Rails to the Chassis