2-4
S
UPER
S
ERVER
6021F
Manual
Installing the Chassis Rails:
Remove the handles on the 6021F chassis (see Figure 2-1) and position the
fixed chassis rail sections along the side of the 6021F chassis making sure
the two screw holes line up. Note that these two rails are left/right spe
cific. Slide the rails on to the hooks on both sides of the chassis. Screw the
rail securely to the side of the chassis, and then reinstall the chassis handle
(see Figure 2-2). Repeat this procedure for the other rail on the other side
of the chassis. You will also need to attach the rail brackets when installng
into a telco rack.
Locking Tabs: As you have seen, both chassis rails have a locking tab,
which serves two functions. The first is to lock the server into place
when installed and pushed fully into the rack, which is its normal position.
Secondly, these tabs also lock the server in place when fully extended
from the rack. This prevents the server from coming completely out of
the rack when you pull it out for servicing.
Figure 2-2. Installing Chassis Rails
Installing the Rack Rails:
Determine where you want to place the SuperServer 6021F in the rack.
(See Rack and Server Precautions in Section 2-3.) Position the fixed rack
rail/sliding rail guide assemblies at the desired location in the rack,
keeping the sliding rail guide facing the inside of the rack. Screw the
assembly securely to the rack using the brackets provided. Attach the
Summary of Contents for SUPERSERVER 6021F
Page 1: ...SUPERSERVER 6021F USER SMANUAL 1 0a SUPER...
Page 10: ...NOTES SUPERSERVER 6021F User s Manual x...
Page 30: ...SUPERSERVER 6021F Manual 3 4 NOTES...
Page 41: ...Chapter 5 Installation 5 7 Installation Figure 5 4 Heat Sink Installation...
Page 60: ...5 26 SUPERSERVER 6021F User s Manual Installation NOTES...
Page 69: ...Chapter 6 Advanced Chassis Setup 6 9 Figure 6 6 Chassis Rear View Power Supply I O Shield...
Page 70: ...6 10 SUPERSERVER 6021F Manual NOTES...
Page 112: ...SUPERSERVER 6021F User s Manual B 10 APPENDIX B NOTES...