ERVER 5013C-M8 User's Manual
2-5
Checking the Motherboard Setup
After you install the 5013C-M8 in the rack, you will need to open the unit to make
sure the motherboard is properly installed and all the connections have been
made.
1. Accessing the inside of the 5013C-M8 (Figure 2-4)
First, release the retention screws that secure the unit to the rack. Grasp the
two handles on either side and pull the unit straight out until it locks (you will
hear a "click"). Next, depress the two buttons on the top of the chassis to
release the top cover. There is a large rectangular recess in the middle front
of the top cover to help you push the cover away from you until it stops. You
can then lift the top cover from the chassis to gain full access to the inside
of the server.
2. Check the CPU (processor)
You may have one processor already installed into the system board.
Each processor should have its own heat sink attached. See Chapter 5
for instructions on processor installation.
3. Check the system memory
Your 5013C-M8 server system may have come with system memory already
installed. Make sure all DIMMs are fully seated in their slots. For details on
adding system memory, refer to Chapter 5.
4. Installing add-on cards
If desired, you can install an add-on card to the system. See Chapter 5
for details on installing a PCI add-on card.
5. Check all cable connections and airflow
Make sure all power and data cables are properly connected and not
blocking the airflow. See Chapter 5 for details on cable connections.
Also, check the air seals for damage. The air seals are located under
the chassis fans and beneath the frame cross section that separates the drive
bay area from the motherboard area of the chassis.
Note: Make sure that the air seals are properly installed.
Summary of Contents for SuperServer 5013C-M8
Page 1: ... SUPER SUPERSERVER 5013C M8 USER S MANUAL Revision 1 0a ...
Page 5: ...v Preface Notes ...
Page 10: ...x Notes SUPERSERVER 5013C M8 User s Manual ...
Page 18: ...1 8 SUPERSERVER 5013C M8 User s Manual Notes ...
Page 27: ...Chapter 2 Server Installation 2 9 Figure 2 4 Accessing the Inside of the SuperServer 5013C M8 ...
Page 32: ...3 4 SUPERSERVER 5013C M8 User s Manual Notes ...
Page 68: ...6 8 SUPERSERVER 5013C M8 User s Manual Notes ...
Page 86: ...A 2 SUPERSERVER 5013C M8 User s Manual Notes ...
Page 92: ...B 6 SUPERSERVER 5013C M8 User s Manual Notes ...