C-2
S
UPER
S
ERVER 5013C-M8 User's Manual
Weight
Gross Weight: 38 lbs. (17.3 kg.)
System Cooling
Three (3) 4-cm high performance fans
System Input Requirements
AC Input Voltage: 100-240 VAC
Rated Input Current: 4A (115V) to 2A (230V)
Rated Input Frequency: 50 to 60 Hz
Power Supply
Rated Output Power: 300W (Model# SP302-1S, Part# PWS-0054)
Rated Output Voltages: +3.3V (15A), +5V (15A), +12V1 (15A), +12V2
(15A), 12Vtotal (20A), -12V (1A), +5Vsb (2A)
BTU Rating
1470 BTUs/hr (for rated output power of 300W)
Operating Environment
Operating Temperature: 10º to 35º C (50º to 95º F)
Non-operating Temperature: -40º to 70º C (-40º to 158º F)
Operating Relative Humidity: 8% to 90% (non-condensing)
Non-operating Relative Humidity: 5 to 95% (non-condensing)
Regulatory Compliance
Electromagnetic Emissions:
FCC Class B, EN 55022 Class B, EN 61000-3-2/-3-3, CISPR 22 Class B
Electromagnetic Immunity:
EN 55024/CISPR 24, (EN 61000-4-2, EN 61000-4-3, EN 61000-4-4,
EN 61000-4-5, EN 61000-4-6, EN 61000-4-8, EN 61000-4-11)
Safety:
EN 60950/IEC 60950-Compliant
UL Listed (USA)
CUL Listed (Canada)
TUV Certified (Germany)
CE Marking (Europe)
Summary of Contents for SuperServer 5013C-M8
Page 1: ... SUPER SUPERSERVER 5013C M8 USER S MANUAL Revision 1 0a ...
Page 5: ...v Preface Notes ...
Page 10: ...x Notes SUPERSERVER 5013C M8 User s Manual ...
Page 18: ...1 8 SUPERSERVER 5013C M8 User s Manual Notes ...
Page 27: ...Chapter 2 Server Installation 2 9 Figure 2 4 Accessing the Inside of the SuperServer 5013C M8 ...
Page 32: ...3 4 SUPERSERVER 5013C M8 User s Manual Notes ...
Page 68: ...6 8 SUPERSERVER 5013C M8 User s Manual Notes ...
Page 86: ...A 2 SUPERSERVER 5013C M8 User s Manual Notes ...
Page 92: ...B 6 SUPERSERVER 5013C M8 User s Manual Notes ...