Chapter 2: Server Installation
25
Figure 2-3. Installing the Inner Rails
Installing The Inner Rails on the Chassis
Installing the Inner Rails
1. Identify the left and right inner rails.
2.
Place the inner rail firmly against the side of the chassis, aligning the T-studs on the
side of the chassis with the slotted holes in the inner rail.
3. Slide the inner rail toward the rear of the chassis and under the T-studs. A spring clip
will snap onto one of the T-studs when it is in place.
4. An optional (M4) screw can be used to secure the rail to the chassis.
Warning
: Do not pick up the server by the front handles. They are designed to pull
the system from a rack only.
4
3
2
MCP-290-11809-0N
Press
* Original setting
* Round cylinder
674 mm to 1048 mm
3
Note
: Drawings are for illustrative purposes. Your chassis may look different.