Chapter 6: Advanced Chassis Setup
6-3
6-3 System
Fans
The SC116 chassis includes four (4) cooling fans. These fans are NOT redundant,
hot-plug and must be replaced when they fail with the power off.
The fans provide the cooling for the system. It is very important that the chassis
top cover is properly installed and making a good seal in order for the cooling air
to circulate properly through the chassis and cool the components. See Figure 6-2.
The SC116 chassis uses counter-rotating fans. Each fan unit is actually made up
of two fans joined back-to-back, which rotate in opposite directions. This counter-
rotating action generates exceptional airfl ow and works to dampen vibration levels.
System Fan Failure
Fan speed is controlled by system temperature via IPMI software. If a fan fails, the
remaining fans will ramp up to full speed. Replace any failed fan at your earliest
convenience with the same type and model (the system can continue to run with
a failed fan).
The SC116 chassis includes four pre-installed fans. One additional open slot is
available so that one more fan may be added if additional cooling is required.
Replacing a System Fan (Figure 6-2)
1. Open the chassis while the system is running to determine which fan has
failed. Never run the server for an extended period of time with the chassis
open.
2. Turn off the power to the system and unplug the power cord from the power
supply.
3. Remove the failed fan's wiring from the fan header on the serverboard.
4. Lift the failed fan from the chassis and pull it completely out.
5. Place the new fan into the vacant space in the housing while making sure
the arrows on the top of the fan (indicating air direction) point in the same
direction as the arrows on the other fans.
6. Reconnect the fan wires to the same chassis fan header as the previous fan.
Summary of Contents for SUPERO SUPERSERVER 1028R-WTR Series
Page 1: ...SUPERSERVER 1028R WTR T SUPER USER S MANUAL Revision 1 0...
Page 5: ...Notes Preface v...
Page 10: ...Notes SUPERSERVER 1028R WTR T USER S MANUAL x...
Page 59: ...Chapter 5 Advanced Serverboard Setup 5 9 Figure 5 3 Heatsink Placement...
Page 120: ...7 32 SUPERSERVER 1028R WTR T USER S MANUAL Notes...
Page 122: ...A 2 SUPERSERVER 1028R WTR T USER S MANUAL Notes...