Chapter 2: Server Installation
2-9
Installing the Chassis into a Rack
1. Confi rm that chassis includes the inner rails and inner rail extensions.
Alsoconfi rm that the outer rails are installed on the rack.
2. Align the chassis inner rails with the front of the out rails on the rack.
3. Slide the chassis rails into the rack rails, keeping the pressure even on both
sides (you may have to depress the locking tabs when inserting). When the
server has been pushed completely into the rack, you should hear the locking
tabs click into position.
4. (Optional) Insert and tighten the thumbscrews that hold the front of the server
to the rack.
Figure 2-5. Installing the Rack Rails