E-11
Appendix E: CSE-PTJBOD-CB3 Power Board Specifications
JP1
JP3
E-9 SC847 JBOD
Cabling
SAS3 I
2
C Cabling in the SC847 JBOD Chassis
Use the diagram below to connect the CSE-PTJBOD-CB3 to the front and rear
backplanes in the SC847 JBOD chassis.
CSE-PTJBOD-CB3
Rear Backplane
BPN-SAS3-847EL1/EL2
Connected to the Primary I
2
C
Connector (SMB)
Front Backplane BPN-SAS3-
846EL1/EL2 Connected to the
I
2
C Connector (I2C0)
Figure E-6: SAS3 I
2
C Cabling in the SC847 JBOD Chassis
CBL-CDAT-0601
CBL-CDAT-0601
Jumper Settings
Jumper
Setting
JP5
Pins 1-2: SAS3 enabled
Pins 2-3: SAS2 enabled and SC847D
When enabling SAS2/SAS3 functionality, use connectors JP1-JP4, (see Page 2-4)
and set the JP5 jumper to pins 1-2 (SAS3) or pins 3-4 (SAS2).
When an SC847D chassis is being used, use connectors J4-J7 (see Page 2-4) and
set the JP5 jumper to pins 2-3.