![Supermicro 7045B-T User Manual Download Page 47](http://html1.mh-extra.com/html/supermicro/7045b-t/7045b-t_user-manual_1404351047.webp)
Chapter 5: Advanced Serverboard Setup
5-13
Overheat/Fan Fail LED (OH)
Connect an LED to the OH connection
on pins 7 and 8 of JF1 to provide ad-
vanced warning of chassis overheat-
ing or fan fail. Refer to the table on
the right for pin defi nitions.
NIC1 LED
The NIC1 (Network Interface Control-
ler) LED connection is located on pins
11 and 12 of JF1. Attach the NIC1
LED cable to display network activity.
Refer to the table on the right for pin
defi nitions.
Power Fail LED
The Power Fail LED connection is
located on pins 5 and 6 of JF1. Re-
fer to the table on the right for pin
defi nitions.
NIC2 LED
The NIC2 (Network Interface Control-
ler) LED connection is located on pins
9 and 10 of JF1. Attach the NIC2
LED cable to display network activity.
Refer to the table on the right for pin
defi nitions.
OH/Fan Fail LED
Pin Defi nitions (JF1)
Pin# Defi nition
7
Vcc
8
Ground
Power Fail LED
Pin Defi nitions (JF1)
Pin# Defi nition
5
Vcc
6
Ground
NIC1 LED
Pin Defi nitions (JF1)
Pin# Defi nition
11
Vcc
12
Ground
NIC2 LED
Pin Defi nitions (JF1)
Pin# Defi nition
9
Vcc
10
Ground
HDD LED
The HDD (IDE Hard Disk Drive) LED
connection is located on pins 13 and
14 of JF1. Attach the IDE hard drive
LED cable to display disk activity.
Refer to the table on the right for pin
defi nitions.
HDD LED
Pin Defi nitions (JF1)
Pin# Defi nition
13
Vcc
14
HD Active
Summary of Contents for 7045B-T
Page 1: ...SUPERSERVER 7045B T USER S MANUAL 1 0a SUPER...
Page 5: ...v Preface Notes...
Page 10: ...Notes x SUPERSERVER 7045B T User s Manual...
Page 30: ...3 4 SUPERSERVER 7045B T User s Manual Notes...
Page 68: ...6 10 SUPERSERVER 7045B T User s Manual Notes...
Page 96: ...A 6 SUPERSERVER 7045B T User s Manual Notes...
Page 102: ...B 6 SUPERSERVER 7045B T User s Manual Notes...
Page 116: ...C 14 SUPERSERVER 7045B T User s Manual Notes...