2-8
S
UPER
S
ERVER 7045B-T User's Manual
2-5 Checking the Serverboard Setup
After setting up the the system, you will need to open the unit to make sure the
serverboard is properly installed and all the connections have been made.
1.
Accessing the inside of the system (see Figure 2-5)
[If rack mounted, fi rst grasp the two handles on either side and pull the unit
straight out until it locks (you will hear a "click").] There are two screws that
secure the cover to the chassis - remove these fi rst. Depress the button on the
top (side if tower) of the chassis to release the cover. You can then lift the cover
from the chassis to gain full access to the inside of the server.
2.
Check
the
CPUs
(processors)
You may have one or two processors already installed into the serverboard. Each
processor should have its own heatsink attached. See Chapter 5 for instructions
on processor installation.
3.
CPU clock ratio setting
The CPU speed should be automatically detected. No jumper or BIOS settings
need
to
be
made.
4.
Check the system memory
Your server may have come with system memory already installed. Make sure
all DIMMs are fully seated in their slots. For details on adding system memory,
refer to Chapter 5.
5.
Installing
add-on
cards
If desired, you can install add-on cards to the system. See Chapter 5 for details
on installing PCI add-on cards.
6.
Check all cable connections and airfl ow
Make sure all power and data cables are properly connected and not blocking
the chassis airfl ow. See Chapter 5 for details on cable connections.
Summary of Contents for 7045B-T
Page 1: ...SUPERSERVER 7045B T USER S MANUAL 1 0a SUPER...
Page 5: ...v Preface Notes...
Page 10: ...Notes x SUPERSERVER 7045B T User s Manual...
Page 30: ...3 4 SUPERSERVER 7045B T User s Manual Notes...
Page 68: ...6 10 SUPERSERVER 7045B T User s Manual Notes...
Page 96: ...A 6 SUPERSERVER 7045B T User s Manual Notes...
Page 102: ...B 6 SUPERSERVER 7045B T User s Manual Notes...
Page 116: ...C 14 SUPERSERVER 7045B T User s Manual Notes...