47
Chapter 4: Motherboard Connections
Power SMB (I
2
C) Header
The Power System Management Bus (I
2
C) connector (JPI
2
C1) monitors the power supply,
fan, and system temperatures. Refer to the table below for pin definitions.
Power SMB Header
Pin Definitions
Pin#
Definition
1
Clock
2
Data
3
PMBUS_Alert
4
Ground
5
+3.3V
4-pin BMC External I
2
C Header
A System Management Bus header for IPMI 2.0 is located at JIPMB1. Connect the appropriate
cable here to use the IPMB I
2
C connection on your system. Refer to the table below for pin
definitions.
External I
2
C Header
Pin Definitions
Pin#
Definition
1
Data
2
Ground
3
Clock
4
No Connection
Chassis Intrusion
A Chassis Intrusion header is located at JL1 on the motherboard. Attach the appropriate cable
from the chassis to inform you of a chassis intrusion when the chassis is opened. Refer to
the table below for pin definitions.
Chassis Intrusion
Pin Definitions
Pin#
Definition
1
Intrusion Input
2
Ground
NVMe I
2
C Header
Connector JNVI
2
C1 is a management header for the Supermicro AOC NVMe PCI-E peripheral
card. Please connect the I
2