Replacing an Exhaust Fan
1. Determine which of the exhaust fans have failed.
2. Remove the cover from the chassis as described previously.
3. Lift the fan housing up and out of the chassis.
4. Remove the failed fan from the fan housing.
5. Place the new fan into the housing while making sure the arrows on the top
of the fan (indicating air direction) point in the same direction as the arrows
on the other fans.
6. Place the fan housing back in the chassis.
7.
Confirm that the fan is working properly before replacing the chassis cover.
Note: serverboard not shown in below image.
Figure 6-8. Replacing an Exhaust Fan