background image

 

-  16  -

                                                                                                            RDO1BP  B

 

CONTROL BOX MOUNTING TEMPLATE 

 
 
 

 

Summary of Contents for RDO-1BP

Page 1: ...801 001 03 ...

Page 2: ... automotive bearing grease Failure to adequately lubricate the springs may result in one or more of the following symptoms a The springs will become rusty over time resulting in extra operating friction between the coils which may cause the AGDO to malfunction b Seasonal temperature changes may cause the Garage Door springs to expand and or contract The resultant increase and or decrease in operat...

Page 3: ...carried out by a technically qualified person Attempting to adjust the Safety Reverse Force setting without suitable technical qualification may result in severe personal injury death and or property damage 26 Keep hands and loose clothing clear of the Garage Door and Product at all times 27 In order for the Safety Obstruction Force System to function it must first encounter an object person on to...

Page 4: ... 4 RDO1BP B OPERATING CONTROLS Fig 1 Fig 1A Fig 2 Fig 2A Fig 3 Fig 3A ...

Page 5: ...or remote mounted push button refer Sec 17 18 22 10 RADIO RECEIVER processes the signal from the hand held transmitter 11 AUTO COURTESY LIGHT is activated automatically each time the opener commences an open or close cycle and remains on for approx 3 minutes 12 JUMPER PLUG J8 switches power supply for use with either one of Safety Beams or External Receiver refer Sec 18 13 OPEN LIMIT CAM is used t...

Page 6: ...al check measurement prior to mounting or moving any garage door brackets Fig 5 C Check For Correct Function Of The Door Before beginning the installation of the AGDO check that the garage door is functioning correctly The garage door must be well balanced and operate smoothly and freely When opened to between 900 1200mm from the floor and released the garage door should remain in one fixed positi...

Page 7: ...tain damage as a result of any water intrusion Water damaged electronics are not covered under the terms of the opener warranty Important Note The control box is not water proof H Battery Charger The plug pack battery charger is provided to keep the batteries charged to an optimum voltage A red coloured LED located on the charger casing will illuminate to indicate that the charger has been connect...

Page 8: ...l not hook on to the screws or if the Control Box does hook on but is loose 1 7 At this stage DO NOT plug the Charger into a power socket 2 Fitting Of Drive Unit To The Door Right Hand Installation Depicted 2 1 Check that the door U bolt is securely tightened on the opposite end of the door to which the Drive Unit will be fitted Fig 7 2 2 Open the door fully and ensure that the bottom stoppers of ...

Page 9: ... forks of the Drive Unit 2 10 Refit the garage door mounting bracket to the wall The U Bolt slots in the door bracket must align with the U bolt mounting slots in the Drive Unit Fig 10 2 11 Important Note In some cases the door mounting bracket may need to be re positioned in order that the U Bolt holes align 2 12 Fully insert the specially supplied U bolt through the Drive Unit and garage door mo...

Page 10: ...re that there are no persons and or property near or directly under the path of the garage door Release Chord Fig 11 Fig 12 5 Fitting of Weight Bar 5 1 Fit the weight bar to the top edge of the garage door bottom rail as depicted in Fig 12 6 Fixing Of Curtain To Drum Wheel 6 1 The garage door curtain must be secured to the drum wheel with suitable fasteners such as self drilling screws or rivets 6...

Page 11: ...am accordingly 9 Connecting to Power Supply 9 1 Connect the AGDO Battery Charger to a properly earthed power supply 9 2 Switch the power on at the power supply the LED on the charger should glow red 10 Door Travel Final Adjustment 10 1 Open the garage door to a midway position and then pull once on the red disengage cord to engage the AGDO to the garage door 10 2 Test the garage door open and clos...

Page 12: ...e adjustment by pressing the red button again This time the door should reach the fully OPEN position without stopping 13 Safety Obstruction Force Testing Close Direction 13 1 With the garage door in the fully open position place a length of timber measuring 100mm x 50mm on the floor directly under the middle of the garage door Fig 14 13 2 With the garage door in the fully open position close the ...

Page 13: ...top right corner of the Control Box Fig 4 15 4 Momentarily press the Code Set button red coding indicator lamp will glow solid 15 5 Momentarily press the hand transmitter button red coding indicator lamp will extinguish 15 6 Momentarily press the hand transmitter button once again red coding indicator lamp will begin to flash once flashing stops the coding sequence has been completed 15 7 Test for...

Page 14: ... A red indicator lamp on the receiver will glow solid once correct alignment has been achieved 19 2 Test the Safety Beam alignment several times each time ensuring that when the Safety Beams are obstructed the red indicator lamp is extinguished and when unobstructed the indicator lamp glows solid 19 3 Firmly tighten the Safety Beam mounting bracket fixing screws 19 4 Installation of Safety Beams i...

Page 15: ... does not close fully Limit micro switch incorrectly adjusted Re adjust limit switch Refer Installation Instruction Item 3 Lights malfunction globe blown Replace with 24VDC 3W globe Door Stops on Upward cycle before reaching the fully open position Door may be obstructed Door springs may have lost tension Safety Obstruction Force may need adjustment Disengage Opener and check door for free movemen...

Page 16: ... 16 RDO1BP B CONTROL BOX MOUNTING TEMPLATE ...