![Superior Xtreme XM Series Manual Download Page 14](http://html1.mh-extra.com/html/superior/xtreme-xm-series/xtreme-xm-series_manual_1403003014.webp)
Superior
PAPER HANDLING SOLUTIONS
14
© 2005-2015 Superior-PHS
1.
Dropper Ext Delay:
(.01 - .99) Dropper
Extend delay is used when the dropper
forks are full in/back (forks not showing)
and it is the delay between when the forks
are full back and before forks Extend back
out. Normally adjusted for greater delay
time when accumulating large stack
heights to allow time for stack to drop
before extending the dropper forks. Press
adjacent time button to bring up keypad.
Enter required delay time, press enter to save and return to Dropper Screen.
2.
Feeder Delay Time:
(.01-.99) Feeder
delay time between when the dropper
forks start to extend back out and the time
when the feeder begins to feed the next
batch. Normally adjusted so the first sheet
of the batch arrives in the dropper at the
same time the forks are fully extended.
Press adjacent time button to bring up
keypad. Enter required delay time, press
enter to save and return to Dropper
Screen.
3.
Dropper On/Off Button:
Press ON/OFF
button to toggle between dropper being
ON and dropper being OFF. When in the
OFF position, dropper forks will retract and
the feeder can be used as a standard
feeder.
4.
Dropper Auto/Manual Button:
Press
Auto/Manual button to toggle between
dropper being in Auto Mode and Manual
Mode. When in the Auto Mode, when
Feeder Cycle Button is pressed or a
Trigger Signal is received, the dropper will retract, then extend, then feeder will feed next